Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4018731
Status: Active
Facility Name: Effingham Equity
Address: North 4th St. Effingham, IL 62401
County: Effingham
Property Parcel: 03-16-012-043
Facility Type: Bulk / Unattended Self-Service
Owner Type: Private
Green Tag Decal: Y003406
Green Tag Issue Date: 6/16/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Effingham Equity
Owner Address: 201 W. Roadway Ave. Effingham, IL 62401
Owner Status: Current Owner
Purchase Date: 8/16/1980
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/17/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 6/16/2023 12/31/2025
Unattended Self Service 6/16/2023 12/31/2025
Self Service 2/9/2007 12/31/2009

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0004597 Effingham Equity Current Owner 8/16/1980

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
95-0729 4/11/1995 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
95-0729 Eligible 4/27/1995 5/11/1995 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Non Ethanol CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 8/16/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/16/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 7/31/2025 7/31/2026
Overfill Prev Device Overfill Drop Tube Valve 7/10/2024 7/10/2027
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/10/2024 7/10/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/31/2025



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 8/16/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/16/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 7/31/2025 7/31/2026
Overfill Prev Device Overfill Drop Tube Valve 7/10/2024 7/10/2027
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket Insert 7/10/2024 7/10/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/31/2025



Tank Number 3

Capacity: 20000 Petroleum Use: None
Product: Dyed Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 8/16/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/16/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 7/31/2025 7/31/2026
Overfill Prev Device Overfill Drop Tube Valve 7/10/2024 7/10/2027
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/10/2024 7/10/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/31/2025



Tank Number 4

Capacity: 20000 Petroleum Use: None
Product: Dyed Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 8/16/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/16/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 7/31/2025 7/31/2026
Overfill Prev Device Overfill Drop Tube Valve 7/10/2024 7/10/2027
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket Insert 7/10/2024 7/10/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/31/2025



Tank Number 5

Capacity: 20000 Petroleum Use: None
Product: Dyed Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 8/16/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/16/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 7/31/2025 7/31/2026
Overfill Prev Device Overfill Drop Tube Valve 7/10/2024 7/10/2027
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/10/2024 7/10/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 7/31/2025
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/1/2021



Tank Number 6

Capacity: 16000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 8/16/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/16/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 7/31/2025 7/31/2026
Overfill Prev Device Overfill Drop Tube Valve 7/10/2024 7/10/2027
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/10/2024 7/10/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/31/2025



Tank Number 7

Capacity: 16000 Petroleum Use: None
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 8/16/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/16/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 7/31/2025 7/31/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 7/31/2025 7/31/2026
Overfill Prev Device Overfill Drop Tube Valve 7/10/2024 7/10/2027
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/10/2024 7/10/2027
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 7/31/2025



Tank Number 9

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/11/1995
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1963 Red Tag Issue Date:
Last Used Date: 6/15/1982 Fee Due: $0.00
Product Date: 1/1/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/11/1995
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: 6/15/1982 Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 12

Capacity: 300 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Pre 1974 CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/1/1970 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID Fleet

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found