Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4008416
Status: Closed
Facility Name: Effingham State Garage
Address: 400 West Wabash
Effingham, IL 62401
County: Effingham
Property Parcel: 03-16-048-068
Facility Type: State
Owner Type: State
Green Tag Decal: W004425
Green Tag Issue Date: 4/12/2021
Green Tag Expiration Date: 7/6/2023

Owner Details

Owner Name: CMS Division of Vehicles
Owner Address: 200 East Ash Street
Springfield, IL 62704
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 12/27/2021

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 4/12/2021 12/31/2023

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0007370 CMS Division of Vehicles Current Owner
U0007245 Illinois Dept. of Central Management Services Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2024-0835 10/29/2024 Removal Log 01295-2024REM
22-0554 6/21/2022 Removal Log 00523-2022REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20190853 Eligible 11/8/2019 11/15/2019 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/6/1990
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/29/2024
OSFM First Notify Date: 10/4/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 5/30/1990 Red Tag Issue Date:
Last Used Date: 7/1/2022 Fee Due: $0.00
Product Date: 5/30/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/23/2021 6/23/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/23/2021 6/23/2022
Overfill Prev Device Overfill Drop Tube Valve 8/12/2019 8/12/2022
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/25/2019 7/25/2022
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/23/2021
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/25/2019



Tank Number 3

Capacity: 2000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 6/21/2022
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found