Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3040140
Status: Active
Facility Name: Rocket Stop
Address: 13925 134th Ave W Taylor Ridge, IL 61284
County: Rock Island
Property Parcel: 22-08-300-026; 22-08-300-027
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001623
Green Tag Issue Date: 12/29/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Roket Stop, Inc.
Owner Address: 13925 134th Avenue W. Taylor Ridge, IL 61284
Owner Status: Current Owner
Purchase Date: 4/27/2023
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/16/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/29/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041054 Roket Stop, Inc. Current Owner 4/27/2023
U0038880 KDR Rocket Stop, LLC Former Owner 5/25/2016
U0036112 RR Rocket Stop, LLC Former Owner 3/28/2011
U0034042 Brown, Barry Former Owner
U0029800 Murdock, Randy Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251402 (Pending)    Issue Date: 6/2/2025    Expiration Date: 8/1/2025    View NOV Form

Tanks Violations
2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Missing handle on STP ground cover- must be removable allow for inspection.
Facility Electrical Does Not Comply
Facility Miscellaneous - All emergency stops are to be indicated by a sign that reads “EMERGENCY STOP” in at least 2-inch red capital letters. Control Station missing sign for Emergency Stop.
2 Miscellaneous - Sensor does not appear to be functioning properly as sensor is submerged in liguid and monitor is not in alarm.
2 Open electrical conduit or junction boxes. - ATG Riser - wires reconnected outside of electrical box.
1 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
2 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress.

NOV Number: E0020251403 (Pending)    Issue Date: 6/2/2025    Expiration Date: 8/1/2025    View NOV Form

Tanks Violations
Facility Fire Extinguishers - Past due for annual testing - Last Test Date 3/2024

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/9/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 12/5/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/5/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/20/2024 12/20/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 12/20/2024 12/20/2025
Overfill Prev Device Overfill Drop Tube Valve 12/13/2023 12/13/2026
Piping Flexible Double Wall Ameron Flex III N/A N/A
Piping Single Wall STP/Tanktop Sump 12/13/2023 12/13/2026
Leak Detect - Piping Sump Sensor 12/20/2024 12/20/2025
Spill Contain Device Single Wall Spill Bucket 12/13/2023 12/13/2026
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Ameron Flex III Precision Test (Piping) Pass 12/20/2024
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Pass 12/21/2023



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/9/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 12/5/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/5/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/20/2024 12/20/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 12/20/2024 12/20/2025
Overfill Prev Device Overfill Drop Tube Valve 12/13/2023 12/13/2026
Piping Flexible Double Wall Ameron Flex III N/A N/A
Piping Single Wall STP/Tanktop Sump 12/13/2023 12/13/2026
Leak Detect - Piping Sump Sensor 8/6/2025 8/6/2026
Spill Contain Device Single Wall Spill Bucket 12/13/2023 12/13/2026
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Ameron Flex III Precision Test (Piping) Pass 12/20/2024
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Pass 12/21/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found