Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3040124
Status: Closed
Facility Name: Peoria City / County Landfill #2
Address: 11501 West Cottonwood Road Brimfield, IL 61517
County: Peoria
Property Parcel:
Facility Type: Landfill
Owner Type: Municipal
Green Tag Decal: Y002348
Green Tag Issue Date: 11/3/2023
Green Tag Expiration Date: 5/1/2025

Owner Details

Owner Name: Waste Management of Illinois, Inc.
Owner Address: 11501 W. Cottonwood Road Brimfield, IL 60148
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/24/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 11/3/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037735 Waste Management of Illinois, Inc. Current Owner
U0029791 Peoria City / County Landfill #2 Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 4/29/2025 Removal Log 00089-2025REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/29/2025
OSFM First Notify Date: 4/17/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 12/14/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/14/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/17/2024 7/17/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 7/17/2024 7/17/2025
Overfill Prev Device Overfill Drop Tube Valve 7/17/2024 7/17/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2024 7/17/2027
Leak Detect - Piping Sump Sensor 7/17/2024 7/17/2025
Spill Contain Device Single Wall Spill Bucket 7/17/2024 7/17/2027
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 7/17/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found