Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
2500 |
|
Petroleum Use: |
|
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/16/1998 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
10/21/1998 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
12/16/1998 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Gravity Feed |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Pneumercator LC1002 |
11/14/2025 |
11/14/2026 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor |
11/14/2025 |
11/14/2026 |
|
Overfill Prev Device
|
Less than 25 gallon fills |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
11/7/2024 |
11/7/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
11/7/2024 |
11/7/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
11/7/2024 |
11/7/2027 |
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
2500 |
|
Petroleum Use: |
|
| Product: |
New Oil |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/16/1998 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
10/21/1998 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/21/1998 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
European with No Test Req Suction |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor |
11/14/2025 |
11/14/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
11/7/2024 |
11/7/2027 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
12/16/2024 |
12/16/2027 |
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
25000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/16/1998 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
10/8/1998 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/8/1998 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
11/14/2025 |
11/14/2026 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor |
11/14/2025 |
11/14/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
12/16/2024 |
12/16/2027 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
11/7/2024 |
11/7/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
11/7/2024 |
11/7/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
11/7/2024 |
11/7/2027 |
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron
|
Precision Test (Piping)
|
Pass
|
11/14/2025
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found