Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3034766
Status: Active
Facility Name: Goodfield Petroleum Inc.
Address: 211 East Peoria Street Goodfield, IL 61742
County: Woodford
Property Parcel: 17-13-208-013
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01047
Green Tag Issue Date: 6/9/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: FRE ONE LLC
Owner Address: 300 N. Martingale Rd., Suite 750 Schaumburg, IL 60173
Owner Status: Current Owner
Purchase Date: 12/3/2025
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041788 FRE ONE LLC Current Owner 12/3/2025
U0005453 Arnold Owens, Inc., d/b/a Freedom Oil Former Owner 12/15/1999
U0011118 Northrup Oil Co/Norco Fuels Former Owner 3/22/1996
U0023261 Freedom Oil Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/29/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 3/22/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/5/2026 3/5/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 3/5/2026 3/5/2027
Overfill Prev Device Overfill Drop Tube Valve 2/26/2025 2/26/2028
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Single Wall STP/Tanktop Sump 2/26/2025 2/26/2028
Leak Detect - Piping Sump Sensor 3/5/2026 3/5/2027
Spill Contain Device Single Wall Spill Bucket 2/26/2025 2/26/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 3/5/2026



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/29/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 3/22/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/20/2025 2/20/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 3/5/2026 3/5/2027
Overfill Prev Device Overfill Drop Tube Valve 2/26/2025 2/26/2028
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Single Wall STP/Tanktop Sump 2/26/2025 2/26/2028
Leak Detect - Piping Sump Sensor 3/5/2026 3/5/2027
Spill Contain Device Single Wall Spill Bucket 2/26/2025 2/26/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 3/5/2026



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/29/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 3/22/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/5/2026 3/5/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 3/5/2026 3/5/2027
Overfill Prev Device Overfill Drop Tube Valve 2/26/2025 2/26/2028
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Single Wall STP/Tanktop Sump 2/26/2025 2/26/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/5/2026 3/5/2027
Spill Contain Device Single Wall Spill Bucket 2/26/2025 2/26/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 3/5/2026



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/29/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 3/22/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/5/2026 3/5/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 3/5/2026 3/5/2027
Overfill Prev Device Overfill Drop Tube Valve 2/26/2025 2/26/2028
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Single Wall STP/Tanktop Sump 2/26/2025 2/26/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/5/2026 3/5/2027
Spill Contain Device Single Wall Spill Bucket 2/26/2025 2/26/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 3/5/2026

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 10A

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/26/2025 2/26/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/5/2026 3/5/2027



Name\ID 10B

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/26/2025 2/26/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/5/2026 3/5/2027



Name\ID 11A/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 11B

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9/10B

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/26/2025 2/26/2028
Leak Detect - Piping Sump Sensor with positive shutdown 3/5/2026 3/5/2027

MFD Motorfuel Dispensing Forms

No Forms Found