Facility Number: 3028977
Status: Closed
Facility Name: Wisslead Oil
Address: 101 East Main Street Raritan, IL 61471
County: Henderson
Property Parcel:
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: Q001175
Green Tag Issue Date: 4/29/2015
Green Tag Expire Date: 12/31/2017
MFD Type: N/A

Owner Details

Owner Name: Raritan Feed & Farm Supply
Owner Address: 101 East Main, P O Box 6 Raritan, IL 61471
Owner Status: Current Owner
Purchase Date: 2/1/1994
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/15/2016

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0027814 Raritan Feed & Farm Supply Current Owner 2/1/1994
U0018457 Raritan Food Mart Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/6/2017
OSFM First Notify Date: 12/17/1991 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 12/4/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/27/2013 9/27/2016
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Vapor Monitoring No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank STIP3 Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 1/20/2011
Leak Detect - Tank Vapor Monitoring Sensor Functional Pass 1/8/2016



Tank Number 2

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/6/2017
OSFM First Notify Date: 12/17/1991 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 12/4/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/27/2013 9/27/2016
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Vapor Monitoring No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank STIP3 Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 1/20/2011
Leak Detect - Tank Vapor Monitoring Sensor Functional Pass 1/8/2016

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found