Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3028099
Status: Active
Facility Name: Air Land Transport Service, Inc.
Address: 1020 West Birchwood Avenue Morton, IL 61550
County: Tazewell
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: BB03835
Green Tag Issue Date: 5/5/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Fleet

Owner Details

Owner Name: Air Land Transport Service, Inc.
Owner Address: PO Box 968 Morton, IL 61550
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/30/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0000279 Air Land Transport Service, Inc. Current Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00668-2026UPG Upgrade Approved / Issued 6/10/2026 6/14/2026 12/15/2026 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/14/1998
OSFM First Notify Date: 9/13/1991 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1902 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/14/1998
OSFM First Notify Date: 9/13/1991 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1902 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 2500 Petroleum Use: Consumptive Use on Premises for Heating
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/14/1998
OSFM First Notify Date: 9/13/1991 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Empty CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 8/10/1987
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 6/30/1988
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 6

Capacity: 25000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/9/1997 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 3/5/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/29/1997

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/22/2026 1/22/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 1/22/2026 1/22/2027
Overfill Prev Device Overfill Drop Tube Valve 6/15/2026 6/15/2029
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 1/29/2025 1/29/2028
Leak Detect - Piping Sump Sensor 1/29/2025 1/29/2028
Spill Contain Device Double Wall Spill Bucket 6/15/2026 6/15/2029
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 1/22/2026



Tank Number 7

Capacity: 5000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/9/1997 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 3/7/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/10/1997

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Gravity Feed Not applicable Not applicable
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Gravity Feed Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 1/22/2026 1/22/2027
Overfill Prev Device Less than 25 gallon fills Not applicable Not applicable
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Double Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 1/29/2025 1/29/2028
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 2/7/2019

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 1 S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 2 S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found