Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
3023763
Status:
Active
Facility Name:
Prairie Farms Dairy, Inc.
Address:
2004 North University Street Peoria, IL 61604
County:
Peoria
Property Parcel:
Facility Type:
Commercial / Retail
Owner Type:
Private
Green Tag Decal:
Z004062
Green Tag Issue Date:
6/27/2024
Green Tag Expiration Date:
12/31/2026
Owner Details
Owner Name:
Prairie Farms Dairy, Inc.
Owner Address:
2004 North University Street Peoria, IL 61604
Owner Status:
Current Owner
Purchase Date:
11/1/1994
Type of Financial Responsibility:
Surety Bond
Financial Responsibility Reporting Due Date:
2/28/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Fleet
6/27/2024
12/31/2026
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0021154
Prairie Farms Dairy, Inc.
Current Owner
11/1/1994
U0012103
Prairie Farms Dairy, Inc.
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
97-2514
12/30/1997
Removal Log
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
97-2514
Eligible
4/14/1998
5/1/1998
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
8/28/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
37
Abandoned Date:
8/15/1988
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
8000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/30/1997
OSFM
First Notify Date:
8/28/1986
Abandoned Material:
Current Age:
22
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
1/1/1989
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
8000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
2/3/1997
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
11/1/1994
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/1/1994
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
11/18/2024
11/18/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300
11/18/2024
11/18/2025
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
11/18/2024
11/18/2025
Overfill Prev Device
Overfill Drop Tube Valve
11/18/2024
11/18/2027
Piping
Fiberglass Chase
N/A
N/A
Piping
Fiberglass Double Wall Ameron
N/A
N/A
Piping
STP/Tanktop Sump containment FRP
11/18/2024
11/18/2027
Leak Detect - Piping
Sump Sensor
11/18/2024
11/18/2025
Spill Contain Device
Single Wall Spill Bucket
11/18/2024
11/18/2027
Tank
Fiberglass Double Wall Owens Corning Brine Filled
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall Ameron
Precision Test (Piping)
Pass
11/18/2024
Piping
Fiberglass Secondary Containment Ameron flexible primary
Precision Test (Piping)
Pass
11/24/2021
Dispenser Information
Name\ID 1 Master
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 2 Satellite
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found