Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3020801
Status: Active
Facility Name: MNA Food Mart
Address: 1672 N. Henderson Galesburg, IL 61401
County: Knox
Property Parcel: 99-04-428-045
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003220
Green Tag Issue Date: 8/9/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Sumbal Corporation
Owner Address: 705 W. Clinton Street Rushville, IL 62681
Owner Status: Current Owner
Purchase Date: 2/20/2024
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 7/29/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/24/2021 12/31/2023

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0032507 Sumbal Corporation Current Owner 2/20/2024
U0040055 Beeline Properties, LLC Former Owner 11/27/2020
U0007221 Illinois Ayers Oil Company Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
01278-2025CAT Cathodic Protection Approved / Issued 9/30/2025 9/30/2025 3/31/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020252520 (Pending)    Issue Date: 9/24/2025    Expiration Date: 11/23/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
Facility Missing copies of Annual Walkthrough Inspection Report.
1, 2, 3, 4 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).

NOV Number: E0020252522 (Pending)    Issue Date: 9/24/2025    Expiration Date: 11/23/2025    View NOV Form

Tanks Violations
Facility A/B operator retraining required as a result of issuance of the Notice of Violation
2, 3, 4 Annual electronic line leak detector test not completed. - Expired 9/11/2025
1, 2, 3, 4 Annual leak detection certification not completed (Required annually). - Expired 9/11/2025
1, 2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP inner covers deteriorated or missing repair or replace inner covers.
3 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP ground covers missining handles- repair or replace to allow for inspection.
3 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP inner covers deteriorated or missing repair or replace inner covers.
4 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP ground covers missining handles- repair or replace to allow for inspection.
4 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP inner covers deteriorated or missing repair or replace inner covers.
1 Miscellaneous - Obtain permit to reintall C/P in Dispenser 9/10, 11/12, 13/14, 15/16
1 Miscellaneous - Three-year third-party testing required on sacrificial anode/cathodic protection system. Perform testing and maintain passing documentation on site for review by OSFM Inspector.
2 Miscellaneous - Obtain permit to reintall C/P in Dispenser 9/10, 11/12, 13/14, 15/16
2 Miscellaneous - Three-year third-party testing required on sacrificial anode/cathodic protection system. Perform testing and maintain passing documentation on site for review by OSFM Inspector.
3 Miscellaneous - Obtain permit to reintall C/P in Dispenser 9/10, 11/12, 13/14, 15/16
3 Miscellaneous - Three-year third-party testing required on sacrificial anode/cathodic protection system. Perform testing and maintain passing documentation on site for review by OSFM Inspector.
4 Miscellaneous - Obtain permit to reintall C/P in Dispenser 9/10, 11/12, 13/14, 15/16
4 Miscellaneous - Three-year third-party testing required on sacrificial anode/cathodic protection system. Perform testing and maintain passing documentation on site for review by OSFM Inspector.
1, 2, 3, 4 Precision tank test required. - A tank precision test is required because of missing passing monthly leak reports.
1, 2, 3, 4 Required monthly tank leak test records not available. - Missing monthly passing reports for the last ten months.
1, 2, 3, 4 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.

NOV Number: E0020252523 (Pending)    Issue Date: 9/24/2025    Expiration Date: 11/23/2025    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Dsipenser 7/8 & 15/16
Facility Miscellaneous - Section 175.210 Attended Self-Service Motor Fuel Dispensing Facilities and Islands All emergency stops are to be indicated by a sign that reads “EMERGENCY STOP” in at least 2-inch red capital letters.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
01-0061 Eligible 1/26/2001 2/23/2001 $10,000
20010061 Eligible 4/21/2023 4/25/2023 $10,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 3/12/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/1/2025 10/1/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/5/2023 5/5/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/1/2025 10/1/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2025 10/1/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2025 10/1/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 10/1/2025 10/1/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 4/21/2023 4/21/2026
Piping Flexible Double Wall Ameron Flex III N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/21/2023 4/21/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/1/2025
Piping Flexible Double Wall Ameron Flex III Precision Test (Piping) Pass 10/1/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 10/1/2025



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 3/12/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/5/2023 5/5/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/1/2025 10/1/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/1/2025 10/1/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2025 10/1/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2025 10/1/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 10/1/2025 10/1/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 4/21/2023 4/21/2026
Piping Flexible Double Wall Ameron Flex III N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/21/2023 4/21/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/1/2025
Piping Flexible Double Wall Ameron Flex III Precision Test (Piping) Pass 10/1/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 10/1/2025



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 3/12/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/1/2025 10/1/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/5/2023 5/5/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/1/2025 10/1/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2025 10/1/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2025 10/1/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 10/1/2025 10/1/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 4/21/2023 4/21/2026
Piping Flexible Double Wall Ameron Flex III N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/21/2023 4/21/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/1/2025
Piping Flexible Double Wall Ameron Flex III Precision Test (Piping) Pass 10/1/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 10/1/2025



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 3/12/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/1/2025 10/1/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/5/2023 5/5/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/1/2025 10/1/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2025 10/1/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/1/2025 10/1/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 10/1/2025 10/1/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 4/21/2023 4/21/2026
Piping Flexible Double Wall Ameron Flex III N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall STP/Tanktop Sump 12/16/2024 12/16/2027
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/21/2023 4/21/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/1/2025
Piping Flexible Double Wall Ameron Flex III Precision Test (Piping) Pass 10/1/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 10/1/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump



Name\ID 17/18

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 19/20

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 21/22

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 23/24

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 25/26

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 27/28

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 29/30

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 31/32

Status: Removed
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump

MFD Motorfuel Dispensing Forms

No Forms Found