Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3017930
Status: Active
Facility Name: Casey's
Address: 1705 Mulholland Nauvoo, IL 62354
County: Hancock
Property Parcel: 01-36-000-682
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000363
Green Tag Issue Date: 3/12/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave. P.O. Box 3004 Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date: 12/1/1984
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 1/29/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner 12/1/1984

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00278-2026UPG Upgrade Approved / Issued 3/12/2026 3/12/2026 9/14/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020260265 (Pending)    Issue Date: 2/3/2026    Expiration Date: 6/5/2026    View NOV Form

Tanks Violations
1, 2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP ground covers missing handle- repair or replace to allow for inspection.
Facility Missing copies of current testing certificates for operator training
Facility Missing list of designated Class A/B & C Operators - Forms can be found at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms
1 Water in containment without required sensors – install cathodic protection on all exposed steel piping or make containment watertight. By 10/13/28, all containments must be watertight and any CP installed in containments must be removed. - STP

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
02-1526 Eligible 8/25/2003 9/4/2003 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 12/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/20/2026 3/20/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 12/10/2025 12/10/2026
Overfill Prev Device Ball Float Vent Valve OPW 53VM 1/22/2024 1/22/2027
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 4/7/2026 4/7/2029
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/6/2024 2/6/2027
Tank Fiberglass Single Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 3/20/2026
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 3/7/2011



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 12/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/10/2025 3/20/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 12/10/2025 12/10/2026
Overfill Prev Device Ball Float Vent Valve OPW 53VM 3/7/2024 3/7/2027
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 4/7/2026 4/7/2029
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/6/2024 2/6/2027
Tank Fiberglass Single Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 3/20/2026
Tank Fiberglass Single Wall Owens Corning Precision Test (Tank) Pass 3/6/2024
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 3/7/2011

Dispenser Information



Name\ID Dispenser 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID Dispenser 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found