Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3017414
Status: Active
Facility Name: 7-Eleven Store #34463
Address: 412 First Avenue Colona, IL 61241
County: Henry
Property Parcel: 06-10-204-024
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01315
Green Tag Issue Date: 5/5/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: 7-Eleven, Inc.
Owner Address: 3200 Hackberry Road - Gas Compliance Irving, TX 75063
Owner Status: Current Owner
Purchase Date: 2/17/2010
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/8/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0014207 7-Eleven, Inc. Current Owner 2/17/2010
U0024175 Reggs, Inc. Former Owner 8/1/1995
U0012623 Remote Service, Inc. Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
11-0924 8/24/2011 Removal Log 00749-2011REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-1171 Eligible 3/29/2010 5/20/2010 $10,000
11-0924 Eligible 9/4/2013 10/21/2013 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/24/2011
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 1/18/2008 1/18/2011
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 11/14/2005 11/14/2010
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/29/2008 12/29/2009
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flexible Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank STIP3 Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/24/2011
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 1/18/2008 1/18/2011
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 11/14/2005 11/14/2010
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/29/2008 12/29/2009
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flexible Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank STIP3 Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/24/2011
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 1/18/2008 1/18/2011
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 11/14/2005 11/14/2010
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/29/2008 12/29/2009
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flexible Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank STIP3 Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/3/2011 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 10/27/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/19/2011

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/3/2025 12/3/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 12/3/2025 12/3/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/3/2025 12/3/2026
Overfill Prev Device Overfill Drop Tube Valve 2/5/2026 2/5/2029
Piping Fiberglass Double Wall A.O. Smith Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 11/11/2025 11/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 11/11/2025 11/11/2028
Spill Contain Device Double Wall Spill Bucket 12/9/2025 12/9/2028
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 5

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/3/2011 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 10/27/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/3/2025 12/3/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 12/3/2025 12/3/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/3/2025 12/3/2026
Overfill Prev Device Overfill Drop Tube Valve 4/16/2026 4/16/2029
Piping Fiberglass Double Wall A.O. Smith Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 11/11/2025 11/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 11/11/2025 11/11/2028
Spill Contain Device Single Wall Spill Bucket 12/9/2025 12/9/2028
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/3/2011 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 10/27/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/3/2025 12/3/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 12/3/2025 12/3/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/3/2025 12/3/2026
Overfill Prev Device Overfill Drop Tube Valve 2/5/2026 2/5/2029
Piping Fiberglass Double Wall A.O. Smith Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 11/11/2025 11/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 11/11/2025 11/11/2028
Spill Contain Device Single Wall Spill Bucket 12/9/2025 12/9/2028
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 7

Capacity: 8000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/3/2011 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 10/27/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/19/2011

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/3/2025 12/3/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 12/3/2025 12/3/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/3/2025 12/3/2026
Overfill Prev Device Overfill Drop Tube Valve 4/16/2026 4/16/2029
Piping Fiberglass Double Wall A.O. Smith Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 11/11/2025 11/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 11/11/2025 11/11/2028
Spill Contain Device Single Wall Spill Bucket 1/24/2023 1/24/2026
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/11/2025 11/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2025 12/3/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/11/2025 11/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2025 12/3/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/11/2025 11/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2025 12/3/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found