Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3016695
Status: Active
Facility Name: Ipava Food & Liquor
Address: 260 West Main Street
Ipava, IL 61441
County: Fulton
Property Parcel: 21-23-06-315-009
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X000147
Green Tag Issue Date: 1/19/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: RekhaNandi Corporation
Owner Address: 3945 W. Argyle Street
Apt. 1
Chicago, IL 60625
Owner Status: Current Owner
Purchase Date: 2/13/2023
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/10/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/19/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040851 RekhaNandi Corporation Current Owner 2/13/2023
U0011269 Ogden Robert L Former Owner 9/1/2000
U0018409 Howards Ser Former Owner 12/31/1967
U0029849 Smith & Smith Enterprises, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/1/1989
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/1/1989
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/1/1989
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 750 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 11/1/1989
OSFM First Notify Date: 12/14/1991 Abandoned Material:
Current Age: 56 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1948 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 750 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 11/1/1989
OSFM First Notify Date: 12/14/1991 Abandoned Material:
Current Age: 56 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1948 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 750 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 11/1/1989
OSFM First Notify Date: 12/14/1991 Abandoned Material:
Current Age: 56 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1948 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 750 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 11/1/1989
OSFM First Notify Date: 12/14/1991 Abandoned Material:
Current Age: 56 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1948 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/14/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 4/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/10/2023 1/10/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/22/2024 3/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 3/22/2024 3/22/2025
Overfill Prev Device Overfill Drop Tube Valve 3/22/2024 3/22/2027
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 3/22/2024 3/22/2027
Leak Detect - Piping Sump Sensor 3/22/2024 3/22/2025
Spill Contain Device Single Wall Spill Bucket 3/22/2024 3/22/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test Pass 3/22/2024



Tank Number 9

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/14/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 4/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/10/2023 1/10/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/22/2024 3/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 3/22/2024 3/22/2025
Overfill Prev Device Overfill Drop Tube Valve 3/22/2024 3/22/2027
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 3/22/2024 3/22/2027
Leak Detect - Piping Sump Sensor 3/22/2024 3/22/2025
Spill Contain Device Single Wall Spill Bucket 3/22/2024 3/22/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test Pass 3/22/2024



Tank Number 10

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/14/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 4/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/10/2023 1/10/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/22/2024 3/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 3/22/2024 3/22/2025
Overfill Prev Device Overfill Drop Tube Valve 3/22/2024 3/22/2027
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 3/22/2024 3/22/2027
Leak Detect - Piping Sump Sensor 3/22/2024 3/22/2025
Spill Contain Device Single Wall Spill Bucket 3/22/2024 3/22/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test Pass 3/22/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms