Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0040334 |
Prospect Gas Mart, Inc. |
Current Owner |
12/15/2020 |
| U0037156 |
RSB Petro, Inc. |
Former Owner |
12/10/2013 |
| U0033571 |
Saba Group, LLC |
Former Owner |
3/31/2006 |
| U0020426 |
Emro Marketing Co |
Former Owner |
4/3/1997 |
| U0026552 |
Speedway, LLC |
Former Owner |
12/27/1996 |
| U0002795 |
Emro Marketing Co |
Former Owner |
12/31/1967 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 2021-0174 |
3/23/2021 |
Abandonment Log |
00240-2021ABN |
| 96-2374 |
12/26/1996 |
Removal Log |
|
| N/A |
2/27/2025 |
Abandonment Log |
00081-2025ABN |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 96-2374 |
Eligible |
4/15/1997
|
5/21/1997
|
$10,000
|
|
| 05-0379 |
Eligible |
7/18/2005
|
8/8/2005
|
$15,000
|
|
| 20210174 |
Eligible |
4/23/2021
|
4/29/2021
|
$5,000
|
Letter
|
Tank Number 6
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/1/1997 |
|
Abandoned Material: |
|
| Current Age: |
29 |
|
Abandoned Date: |
|
| Install Date: |
12/27/1996 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/6/1997 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
8/13/2025 |
8/13/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
8/17/2026 |
8/17/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus |
8/17/2026 |
8/17/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/13/2025 |
8/13/2028 |
|
Piping
|
Fiberglass Single Wall Piping Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
8/13/2025 |
8/13/2028 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping Ameron
|
Precision Test (Piping)
|
Pass
|
8/17/2026
|
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Pass
|
8/23/2022
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries
|
Precision Test (Tank)
|
Pass
|
10/23/2012
|
Tank Number 7
| Capacity: |
4000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Abandoned in place |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/1/1997 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
29 |
|
Abandoned Date: |
2/27/2025 |
| Install Date: |
12/27/1996 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
4/2/2019 |
|
Fee Due: |
$0.00 |
| Product Date: |
1/6/1997 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
12/27/2022 |
12/27/2025 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
European with No Test Req Suction |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
9/7/2018 |
9/7/2021 |
|
Piping
|
Fiberglass Single Wall Piping Ameron |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries
|
Precision Test (Tank)
|
Pass
|
10/10/2012
|
Tank Number 8
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
12/26/1996 |
|
OSFM
First Notify Date: |
4/18/1986 |
|
Abandoned Material: |
|
| Current Age: |
19 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
12/25/1996 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 9
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
12/26/1996 |
|
OSFM
First Notify Date: |
4/18/1986 |
|
Abandoned Material: |
|
| Current Age: |
19 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
12/25/1996 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 10
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/18/1986 |
|
Abandoned Material: |
|
| Current Age: |
41 |
|
Abandoned Date: |
|
| Install Date: |
8/1/1985 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/1/1985 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
8/13/2025 |
8/13/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
8/13/2025 |
8/13/2028 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
8/17/2026 |
8/17/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus |
8/17/2026 |
8/17/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/13/2025 |
8/13/2028 |
|
Piping
|
Fiberglass Single Wall Piping Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket Insert |
8/13/2025 |
8/13/2028 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping Ameron
|
Precision Test (Piping)
|
Pass
|
8/17/2026
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries
|
Precision Test (Tank)
|
Pass
|
10/10/2012
|
|
Tank
|
STIP3 Single Wall
|
Precision Test (Tank)
|
Pass
|
8/23/2022
|
Tank Number 11
| Capacity: |
10000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/18/1986 |
|
Abandoned Material: |
|
| Current Age: |
41 |
|
Abandoned Date: |
|
| Install Date: |
8/1/1985 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/1/1985 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
8/13/2025 |
8/13/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
8/13/2025 |
8/13/2028 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
8/17/2026 |
8/17/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus |
8/17/2026 |
8/17/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/13/2025 |
8/13/2028 |
|
Piping
|
Fiberglass Single Wall Piping Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
8/13/2025 |
8/13/2028 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping Ameron
|
Precision Test (Piping)
|
Pass
|
8/17/2026
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries
|
Precision Test (Tank)
|
Pass
|
10/23/2012
|
|
Tank
|
STIP3 Single Wall
|
Precision Test (Tank)
|
Pass
|
8/23/2022
|
Tank Number 12
| Capacity: |
4000 |
|
Petroleum Use: |
None |
| Product: |
Kerosene |
|
CERCLA Substance: |
|
| Status: |
Abandoned in place |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
1/19/1990 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
37 |
|
Abandoned Date: |
3/23/2021 |
| Install Date: |
9/18/1989 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
9/23/2016 |
|
Fee Due: |
$0.00 |
| Product Date: |
9/18/1989 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/21/2016 |
10/21/2019 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
European with No Test Req Suction |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping Ameron |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries
|
Precision Test (Tank)
|
Pass
|
10/10/2012
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found