Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3013263
Status: Active
Facility Name: Yoduinder Food Mart, Inc.
Address: 2961 11th Street Rock Island, IL 61201
County: Rock Island
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01343
Green Tag Issue Date: 9/5/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Jeet Singh d/b/a Aman Food & Gas
Owner Address: 1830 5th Avenue Moline, IL 61265
Owner Status: Current Owner
Purchase Date: 4/5/2005
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/5/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/5/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034255 Jeet Singh d/b/a Aman Food & Gas Current Owner 4/5/2005
U0030107 Singh, Jeet Former Owner 5/5/2004
U0025378 K N T Corp Former Owner 11/15/1995
U0000562 Amoco Oil Co Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
01078-2025CAT Cathodic Protection Approved / Issued 8/18/2025 8/18/2025 2/18/2026 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
91-0826 Eligible 8/6/1998 9/9/1998 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1995
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 10/1/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1995
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 10/1/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1995
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 10/1/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1995
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 10/1/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/1995 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 11/15/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/15/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/18/2025 8/18/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/18/2025 8/18/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/18/2025 8/18/2028
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/10/2025 7/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/7/2024 10/7/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/7/2024 10/7/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 10/19/2023 10/19/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/19/2023 10/19/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025
Spill Contain Device Single Wall Spill Bucket 10/19/2023 10/19/2026
Tank Composite Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 7/10/2025
Tank Composite Double Wall Precision Test (Tank) Pass 7/10/2025



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/1995 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 11/15/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/15/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/18/2025 8/18/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/18/2025 8/18/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/18/2025 8/18/2028
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/10/2025 7/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/7/2024 10/7/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/7/2024 10/7/2025
Overfill Prev Device Overfill Drop Tube Valve 10/19/2023 10/19/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/19/2023 10/19/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025
Spill Contain Device Single Wall Spill Bucket 10/19/2023 10/19/2026
Tank Composite Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 7/10/2025
Tank Composite Double Wall Precision Test (Tank) Pass 7/10/2025



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/1995 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 11/15/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/15/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/18/2025 8/18/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/18/2025 8/18/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/18/2025 8/18/2028
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/10/2025 7/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/7/2024 10/7/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/7/2024 10/7/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 10/19/2023 10/19/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/19/2023 10/19/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025
Spill Contain Device Single Wall Spill Bucket 10/19/2023 10/19/2026
Tank Composite Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 7/10/2025
Tank Composite Double Wall Precision Test (Tank) Pass 7/10/2025



Tank Number 8

Capacity: 275 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 10/1/1995
OSFM First Notify Date: 8/6/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 550 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 10/1/1995
OSFM First Notify Date: 8/6/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found