Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3011922
Status: Active
Facility Name: Beck Oil Company
Address: 401 East 2nd Street Kewanee, IL 61443
County: Henry
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003349
Green Tag Issue Date: 10/16/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Beck Oil Company of Illinois
Owner Address: 850 E. Thompson St. Princeton, IL 61356
Owner Status: Current Owner
Purchase Date: 4/15/1968
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/16/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0001282 Beck Oil Company of Illinois Current Owner 4/15/1968

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251758 (Pending)    Issue Date: 7/10/2025    Expiration Date: 9/8/2025    View NOV Form

Tanks Violations
5 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Spill bucket inner lid needs repair or replacement
7 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP inner cover (has large hole) damaged repair or replace
Facility Electrical Does Not Comply - ATG riser has open electrical -wires connected outside of electrical box.
5, 7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.

NOV Number: E0020251760 (Pending)    Issue Date: 7/10/2025    Expiration Date: 9/8/2025    View NOV Form

Tanks Violations
Facility Fire Extinguishers - 2 4A:60BC extinguishers not provided, 1 at or near control station and 1 in the dispensing areas
Facility Miscellaneous
Facility Miscellaneous - Section 175.210 Attended Self-Service Motor Fuel Dispensing Facilities and Islands All emergency stops are to be indicated by a sign that reads “EMERGENCY STOP” in at least 2-inch red capital letters.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
96-2092 11/8/1996 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
96-2092 Eligible 12/4/1998 1/21/1999 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/8/1996
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 6/1/1968 Red Tag Issue Date:
Last Used Date: 11/1/1996 Fee Due: $0.00
Product Date: 6/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/8/1996
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 6/1/1972 Red Tag Issue Date:
Last Used Date: 11/1/1996 Fee Due: $0.00
Product Date: 6/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/8/1996
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 6/1/1956 Red Tag Issue Date:
Last Used Date: 11/1/1996 Fee Due: $0.00
Product Date: 6/1/1956

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 560 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Pre 1974 CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 1/1/1902 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/21/1997 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 11/12/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/7/2025 4/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 4/7/2025 4/7/2026
Overfill Prev Device Ball Float Vent Valve EBW 308 4/7/2025 4/7/2028
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/7/2025 4/7/2028
Leak Detect - Piping Sump Sensor 4/7/2025 4/7/2026
Spill Contain Device Single Wall Spill Bucket 4/7/2025 4/7/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Western Co-Flex Precision Test (Piping) Pass 4/7/2025



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/21/1997 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 11/12/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/7/2025 4/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 4/7/2025 4/7/2026
Overfill Prev Device Ball Float Vent Valve EBW 308 4/7/2025 4/7/2028
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/7/2025 4/7/2028
Leak Detect - Piping Sump Sensor 4/7/2025 4/7/2026
Spill Contain Device Single Wall Spill Bucket 4/7/2025 4/7/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Western Co-Flex Precision Test (Piping) Pass 4/7/2025



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/21/1997 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 11/12/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/7/2025 4/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 4/7/2025 4/7/2026
Overfill Prev Device Ball Float Vent Valve EBW 308 4/7/2025 4/7/2028
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/7/2025 4/7/2028
Leak Detect - Piping Sump Sensor 4/7/2025 4/7/2026
Spill Contain Device Single Wall Spill Bucket 4/7/2025 4/7/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Western Co-Flex Precision Test (Piping) Pass 4/7/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found