Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
B-11 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
7/20/2000 |
|
Abandoned Material: |
|
| Current Age: |
37 |
|
Abandoned Date: |
|
| Install Date: |
1/4/1989 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
2/26/2026 |
2/26/2027 |
|
Leak Detect - Piping
|
Siphon Bar |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
2/26/2026 |
2/26/2027 |
|
Overfill Prev Device
|
Ball Float Vent Valve |
3/3/2025 |
3/3/2028 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/3/2025 |
3/3/2028 |
Leak Detect - Piping
|
Sump Sensor |
3/3/2025 |
3/3/2028 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
3/3/2025 |
3/3/2028 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Piping
|
Siphon Bar
|
Functional
|
Pass
|
2/26/2026
|
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
B-11 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
7/20/2000 |
|
Abandoned Material: |
|
| Current Age: |
37 |
|
Abandoned Date: |
|
| Install Date: |
1/4/1989 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Siphon Bar |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
2/26/2026 |
2/26/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
4/2/2025 |
4/2/2028 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/3/2025 |
3/3/2028 |
Leak Detect - Piping
|
Sump Sensor |
3/3/2025 |
3/3/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
3/26/2025 |
3/26/2028 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Piping
|
Siphon Bar
|
Functional
|
Pass
|
2/26/2026
|
Tank Number 3
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
7/20/2000 |
|
Abandoned Material: |
|
| Current Age: |
37 |
|
Abandoned Date: |
|
| Install Date: |
1/4/1989 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
2/26/2026 |
2/26/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
2/26/2026 |
2/26/2027 |
|
Overfill Prev Device
|
Ball Float Vent Valve |
3/3/2025 |
3/3/2028 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/3/2025 |
3/3/2028 |
Leak Detect - Piping
|
Sump Sensor |
3/3/2025 |
3/3/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
3/26/2025 |
3/26/2028 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 4
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/10/2008 |
|
Abandoned Material: |
|
| Current Age: |
18 |
|
Abandoned Date: |
|
| Install Date: |
8/28/2008 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/28/2008 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
2/26/2026 |
2/26/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
2/26/2026 |
2/26/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
2/26/2026 |
2/26/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
4/2/2025 |
4/2/2028 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/3/2025 |
3/3/2028 |
Leak Detect - Piping
|
Sump Sensor |
3/3/2025 |
3/3/2028 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
3/3/2025 |
3/3/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 5
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/1/1986 |
|
Abandoned Material: |
|
| Current Age: |
60 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1966 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 6
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/1/1986 |
|
Abandoned Material: |
|
| Current Age: |
60 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1966 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 7
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/1/1986 |
|
Abandoned Material: |
|
| Current Age: |
60 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1966 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/2
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
3/3/2025
|
3/3/2028
|
Leak Detect - Piping
|
Sump Sensor |
2/26/2026
|
2/26/2027
|
Name\ID 3/4
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
3/3/2025
|
3/3/2028
|
Leak Detect - Piping
|
Sump Sensor |
2/26/2026
|
2/26/2027
|
Name\ID DSL
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
3/3/2025
|
3/3/2028
|
Leak Detect - Piping
|
Sump Sensor |
2/26/2026
|
2/26/2027
|
Name\ID DSL S
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
3/3/2025
|
3/3/2028
|
Leak Detect - Piping
|
Sump Sensor |
2/26/2026
|
2/26/2027
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found