Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3006048
Status: Active
Facility Name: Aman 1 LLC
Address: 125 19th Ave. Moline, IL 61265
County: Rock Island
Property Parcel: 17-06-214-028
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01427
Green Tag Issue Date: 3/24/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Aman 1, LLC
Owner Address: 125 19th Avenue Moline, IL 61265
Owner Status: Current Owner
Purchase Date: 1/22/2024
Type of Financial Responsibility: Certificate of Deposit and Commercial Insurance
Financial Responsibility Reporting Due Date: 3/24/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/24/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041455 Aman 1, LLC Current Owner 1/22/2024
U0038080 Aman, L.L.C. Former Owner 11/12/2015
U0035995 Petro Gold, Inc. Former Owner 10/6/2010
U0035995 Petro Gold, Inc. Former Owner 10/6/2010
U0032276 Sethu Oil, Inc. Former Owner 8/4/2004
U0031565 Famy, Inc. Former Owner 8/4/2004
U0029789 Clark Retail Enterprises, Inc. Former Owner 3/7/2001
U0015991 Wareco Service, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251893 (Pending)    Issue Date: 7/24/2025    Expiration Date: 9/22/2025    View NOV Form

Tanks Violations
1, 3, 4 Miscellaneous - Operating as an unattended self service facility without permit.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
11-0148 6/2/2011 Abandonment Log 00172-2011ABN
14-0460 6/16/2014 Abandonment Log 00356-2014ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
14-0460 Eligible 7/21/2014 9/8/2014 $5,000
11-0148 Eligible 10/22/2014 12/12/2014 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1985 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 12/10/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/10/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 10/26/2022 10/26/2025
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 10/26/2022 10/26/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/28/2024 10/28/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 2001with SCALD 2/25/2025 2/25/2026
Overfill Prev Device Overfill Drop Tube Valve 10/26/2022 10/26/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/26/2022 10/26/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/28/2024
Tank STIP3 Single Wall Precision Test (Tank) Pass 11/1/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/5/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 14 Abandoned Date: 6/2/2011
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/2007 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal
Leak Detect - Piping Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/5/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 4/5/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/5/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 10/26/2022 10/26/2025
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 10/26/2022 10/26/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/28/2024 10/28/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 2001with SCALD 10/28/2024 10/28/2025
Overfill Prev Device Overfill Drop Tube Valve 10/26/2022 10/26/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/26/2022 10/26/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/28/2024
Tank STIP3 Single Wall Precision Test (Tank) Pass 11/1/2024



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/5/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 4/5/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/5/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/26/2022 10/26/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 10/26/2022 10/26/2025
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 10/26/2022 10/26/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/28/2024 10/28/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 2001with SCALD 10/28/2024 10/28/2025
Overfill Prev Device Overfill Drop Tube Valve 10/26/2022 10/26/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/26/2022 10/26/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/28/2024
Tank STIP3 Single Wall Precision Test (Tank) Pass 11/1/2024



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/5/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 37 Abandoned Date: 6/16/2014
Install Date: 4/5/1988 Red Tag Issue Date:
Last Used Date: 12/1/2007 Fee Due: $0.00
Product Date: 4/5/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/13/2012 12/13/2015
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 12/13/2012 12/13/2015
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 with SCALD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/1/1987
OSFM First Notify Date: 12/10/1985 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/1/1987
OSFM First Notify Date: 12/10/1985 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/1/1987
OSFM First Notify Date: 12/10/1985 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found