Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3005697
Status: Closed
Facility Name: Pekin Municipal Airport
Address: 13906 Airport Lane Pekin, IL 61554
County: Tazewell
Property Parcel: 10-10-33-100-007
Facility Type: Airport
Owner Type: Municipal
Green Tag Decal: Extend
Green Tag Issue Date: 1/8/2026
Green Tag Expire Date: 2/28/2026
MFD Type: N/A

Owner Details

Owner Name: City of Pekin
Owner Address: 111 South Capitol St. Pekin, IL 61554
Owner Status: Current Owner
Purchase Date: 8/1/1962
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038781 City of Pekin Current Owner 8/1/1962
U0011681 Pekin Municipal Airport Former Owner 6/15/1959

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00260-2026REM Removal Approved / Issued 3/9/2026 3/9/2026 9/9/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020241528 (Referred to Legal)    Issue Date: 5/29/2024    Expiration Date: 7/28/2024    View NOV Form

Tanks Violations
1, 2 Tank internal lining inspection past due (Required every 5 years). - Liner needs to tested and pass, tanks need to removed or replaced or a permit on file.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Jet A CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/15/2026
OSFM First Notify Date: 3/24/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/29/2025 1/29/2028
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 4/12/2019 4/12/2024
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 1/29/2025 1/29/2026
Overfill Prev Device Overfill Drop Tube Valve 1/29/2025 1/29/2028
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/29/2025 1/29/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Aviation Gas CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/15/2026
OSFM First Notify Date: 3/24/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/29/2025 1/29/2028
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 4/12/2019 4/12/2024
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 1/29/2025 1/29/2026
Overfill Prev Device Overfill Drop Tube Valve 1/29/2025 1/29/2028
Piping Flexible Double Wall A.P.T. Poly Tech P200SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/29/2025 1/29/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms