Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
3002585
Status:
Active
Facility Name:
Law Service & Repair, Inc.
Address:
101 N. Madison Street
Carthage, IL 62321
County:
Hancock
Property Parcel:
Facility Type:
Full Service Station
Owner Type:
Private
Green Tag Decal:
Z000378
Green Tag Issue Date:
4/22/2024
Green Tag Expiration Date:
12/31/2026
Owner Details
Owner Name:
Law Service & Repair Inc.
Owner Address:
101 N. Madison Street
Carthage, IL 62321
Owner Status:
Current Owner
Purchase Date:
6/1/2002
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
9/25/2025
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Full Service
4/22/2024
12/31/2026
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0031402
Law Service & Repair Inc.
Current Owner
6/1/2002
U0016695
Wright Petroleum Company, Inc.
Former Owner
4/1/1984
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
00-2131
1/9/2001
Removal Log
02107-2000REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
00-2131
Eligible
12/1/2000
12/19/2000
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
8000
Petroleum Use:
Product:
Gasoline - Mid-grade
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/18/1986
Abandoned Material:
Current Age:
43
Abandoned Date:
Install Date:
3/18/1982
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Isolation Boots Flex Connector
N/A
N/A
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
2/13/2025
2/13/2026
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300i with CSLD
2/13/2025
2/13/2026
Overfill Prev Device
Overfill Drop Tube Valve
2/13/2025
2/13/2028
Piping
Fiberglass Single Wall Piping A.O. Smith
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
2/13/2025
2/13/2028
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
8000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/18/1986
Abandoned Material:
Current Age:
46
Abandoned Date:
Install Date:
3/2/1979
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Isolation Boots Flex Connector
N/A
N/A
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
2/13/2025
2/13/2026
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300i with CSLD
2/13/2025
2/13/2026
Overfill Prev Device
Overfill Drop Tube Valve
2/13/2025
2/13/2028
Piping
Fiberglass Single Wall Piping A.O. Smith
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
2/13/2025
2/13/2028
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
1000
Petroleum Use:
Product:
Gasoline - Mid-grade
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/18/1986
Abandoned Material:
Current Age:
43
Abandoned Date:
Install Date:
3/2/1982
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Isolation Boots Flex Connector
N/A
N/A
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
2/13/2025
2/13/2026
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300i with CSLD
2/13/2025
2/13/2026
Overfill Prev Device
Overfill Drop Tube Valve
2/13/2025
2/13/2028
Piping
Fiberglass Single Wall Piping A.O. Smith
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
2/13/2025
2/13/2028
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
1000
Petroleum Use:
Product:
Kerosene
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/9/2001
OSFM
First Notify Date:
3/18/1986
Abandoned Material:
Current Age:
19
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/22/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 2/3
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 4/5
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found