Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3001237
Status: Active
Facility Name: Tremont Oil Company
Address: 200 East Pearl Street Tremont, IL 61568
County: Tazewell
Property Parcel: 12-12-18-327-015
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00517
Green Tag Issue Date: 2/24/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Tremont Oil Company
Owner Address: 200 E. Pearl St. P.O. Box Tremont, IL 61568
Owner Status: Current Owner
Purchase Date: 5/18/1992
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 5/19/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/24/2025 12/31/2027
Full Service 2/16/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0015189 Tremont Oil Company Current Owner 5/18/1992

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00686-2025ABN Abandon in Place Approved / Issued 6/3/2025 6/4/2025 12/4/2025 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 6/13/2025 Abandonment Log 00686-2025ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20250382 Eligible 7/23/2025 7/24/2025 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 7

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 6/24/1987
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 6/24/1987
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 6/24/1987
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 6/24/1987
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 42 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 2000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1988 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 7/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/15/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/25/2023 9/25/2026
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 9/25/2023 9/25/2026
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 12

Capacity: 1000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1988 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 7/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/15/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/25/2023 9/25/2026
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 9/25/2023 9/25/2026
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 9/10/2019



Tank Number 13

Capacity: 560 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 6/24/1987
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 14

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/1992 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 5/11/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/18/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/25/2023 9/25/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/18/2024 9/18/2025
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/18/2024



Tank Number 15

Capacity: 15000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/1992 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 5/11/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/18/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/25/2023 9/25/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/18/2024 9/18/2025
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/18/2024



Tank Number 16

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/1992 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 5/11/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/18/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/25/2023 9/25/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/18/2024 9/18/2025
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/18/2024



Tank Number 17

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/1992 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 5/11/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/18/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/25/2023 9/25/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/18/2024 9/18/2025
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/18/2024



Tank Number 18

Capacity: 6000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/25/1992 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 5/11/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/18/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/25/2023 9/25/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/18/2024 9/18/2025
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/18/2024



Tank Number 19

Capacity: 5000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/1992 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 5/11/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/18/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/25/2023 9/25/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/18/2024 9/18/2025
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/18/2024



Tank Number 20

Capacity: 1000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1988 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 7/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/15/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/25/2023 9/25/2026
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 9/25/2023 9/25/2026
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 21

Capacity: 300 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 6/24/1987
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 22

Capacity: 300 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 6/24/1987
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 23

Capacity: 1000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 38 Abandoned Date: 6/13/2025
Install Date: 7/15/1987 Red Tag Issue Date:
Last Used Date: 9/29/2023 Fee Due: $0.00
Product Date: 7/15/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 11/16/2023 11/16/2026
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 11/16/2023 11/16/2026
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 9/25/2023 9/25/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/25/2023 9/25/2024
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/25/2023 9/25/2024
Overfill Prev Device Overfill Drop Tube Valve 9/23/2021 9/23/2024
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/23/2021 9/23/2024
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 9/25/2023



Tank Number 24

Capacity: 560 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1988 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 7/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/15/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/25/2023 9/25/2026
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 9/25/2023 9/25/2026
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Petro Vend Site Sentinel Model II 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 25

Capacity: 560 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/18/2001
OSFM First Notify Date: 11/16/1988 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 7/15/1987 Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date: 7/15/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 10/11

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 12/13

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 6/7

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 8/9

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms