Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3000358
Status: Closed
Facility Name: Dayton Freight Lines, Inc.
Address: 7 Altorfer Lane
East Peoria, IL 61611
County: Tazewell
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: X003728
Green Tag Issue Date: 6/14/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Dayton Freight Lines, Inc.
Owner Address: 6450 Poe Avenue, Suite 311
Dayton, OH 45414
Owner Status: Current Owner
Purchase Date: 1/16/2000
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/11/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 9/3/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0029281 Dayton Freight Lines, Inc., Current Owner 1/16/2000
U0012151 Preston Truck Inc Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 11/26/2024 Removal Log 00553-2024REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/26/2024
OSFM First Notify Date: 12/23/1985 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/16/2024 4/16/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 4/16/2024 4/16/2025
Overfill Prev Device Overfill Drop Tube Valve 5/1/2023 5/1/2026
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 4/16/2024 4/16/2025
Spill Contain Device Single Wall Spill Bucket 8/15/2024 8/15/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 4/16/2024



Tank Number 2

Capacity: 1500 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/5/1998 Abandoned Material:
Current Age: 55 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 1500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/22/1999
OSFM First Notify Date: 6/5/1998 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1500 Petroleum Use:
Product: Ethylene Glycol CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/22/1999
OSFM First Notify Date: 6/5/1998 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 1500 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 4/22/1999
OSFM First Notify Date: 6/5/1998 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 1500 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/22/1999
OSFM First Notify Date: 2/9/1999 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 9/1/1976 Red Tag Issue Date:
Last Used Date: 12/20/1997 Fee Due: $0.00
Product Date: 9/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 1S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms