Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2047978
Status: Installed/Not in Use
Facility Name: Woodman's Markets Gas Lube
Address: 11861 S Rt.59 Plainfield, IL 60585
County: Will
Property Parcel: 07-01-22-300-017-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal:
Green Tag Issue Date:
Green Tag Expire Date:
MFD Type: N/A

Owner Details

Owner Name: Woodman's Food Market, Inc.
Owner Address: 2631 Liberty Lane Janesville, WI 535450741
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/28/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030284 Woodman's Food Market, Inc. Current Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00983-2026INS Install Approved / Issued 8/18/2026 8/18/2026 2/18/2027 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 30000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/8/2026 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 2/27/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/21/2026 9/21/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 9/21/2026 9/21/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/21/2026 9/21/2027
Overfill Prev Device Overfill Drop Tube Valve 9/21/2026 9/21/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/21/2026 4/21/2029
Spill Contain Device Double Wall Spill Bucket 4/21/2026 4/21/2029
Tank Composite Double Wall Lannon Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 9/21/2026
Tank Composite Double Wall Lannon Precision Test (Tank) Pass 9/21/2026



Tank Number 2

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/8/2026 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 3/5/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/21/2026 9/21/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 9/21/2026 9/21/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/21/2026 9/21/2027
Overfill Prev Device Overfill Drop Tube Valve 9/21/2026 9/21/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/21/2026 4/21/2029
Spill Contain Device Double Wall Spill Bucket 4/21/2026 4/21/2029
Tank Composite Double Wall Lannon Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 9/21/2026
Tank Composite Double Wall Lannon Precision Test (Tank) Pass 9/21/2026



Tank Number 3

Capacity: 6000 Petroleum Use: Dispensing
Product: Diesel Fuel CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/8/2026 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 2/27/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/21/2026 9/21/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 9/21/2026 9/21/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/21/2026 9/21/2027
Overfill Prev Device Overfill Drop Tube Valve 9/21/2026 9/21/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/21/2026 4/21/2029
Spill Contain Device Double Wall Spill Bucket 4/21/2026 4/21/2029
Tank Composite Double Wall Lannon Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 9/21/2026
Tank Composite Double Wall Lannon Precision Test (Tank) Pass 9/21/2026



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/8/2026 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 2/27/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/21/2026 9/21/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 9/21/2026 9/21/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/21/2026 9/21/2027
Overfill Prev Device Overfill Drop Tube Valve 9/21/2026 9/21/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/21/2026 4/21/2029
Spill Contain Device Double Wall Spill Bucket 4/21/2026 4/21/2029
Tank Composite Double Wall Lannon Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 9/21/2026
Tank Composite Double Wall Lannon Precision Test (Tank) Pass 9/21/2026



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/8/2026 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 2/27/2026 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/21/2026 9/21/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 9/21/2026 9/21/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/21/2026 9/21/2027
Overfill Prev Device Overfill Drop Tube Valve 9/21/2026 9/21/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/21/2026 4/21/2029
Spill Contain Device Double Wall Spill Bucket 4/21/2026 4/21/2029
Tank Composite Double Wall Lannon Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 9/21/2026
Tank Composite Double Wall Lannon Precision Test (Tank) Pass 9/21/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 23/24

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 25/26

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 27/28

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 29/30

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 31/32

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/21/2026 4/21/2029
Leak Detect - Piping Sump Sensor with positive shutdown 9/21/2026 9/21/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2047978 Woodman's Markets Gas Lube Plainfield 08/18/2026 Letter Form
2047978 Woodman's Markets Gas Lube Plainfield 02/12/2026 Letter Form