Facility Details
Facility Number:
2047467
Status:
Active
Facility Name:
Thornton's #348
Address:
15925 W 159th Street Lockport, IL 60491
County:
Will
Property Parcel:
16-05-20-100-002-0000
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA01981
Green Tag Issue Date:
7/1/2025
Green Tag Expiration Date:
12/31/2027
Owner Details
Owner Name:
Thorntons, LLC
Owner Address:
2600 James Thornton Way Louisville, KY 40245
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
2/18/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
7/1/2025
12/31/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0039521
Thorntons, LLC
Current Owner
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
00210-2025UPG
Upgrade
Approved / Issued
2/25/2025
2/25/2025
8/26/2025
Documents
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
20000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/28/2023
Abandoned Material:
Current Age:
2
Abandoned Date:
Install Date:
12/6/2022
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/18/2025
4/18/2026
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor
4/18/2025
4/18/2026
Overfill Prev Device
Overfill Alarm
5/8/2023
5/8/2026
Overfill Prev Device
Overfill Drop Tube Valve
5/8/2023
5/8/2026
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Spill Contain Device
Double Wall Spill Bucket
6/25/2025
6/25/2028
Tank
Fiberglass Brine Filled Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
5/8/2023
Tank
Fiberglass Brine Filled Double Wall XERXES
Precision Test (Tank)
Pass
5/8/2023
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/28/2023
Abandoned Material:
Current Age:
2
Abandoned Date:
Install Date:
12/6/2022
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/18/2025
4/18/2026
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor
4/18/2025
4/18/2026
Overfill Prev Device
Overfill Alarm
5/8/2023
5/8/2026
Overfill Prev Device
Overfill Drop Tube Valve
5/8/2023
5/8/2026
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Spill Contain Device
Double Wall Spill Bucket
2/26/2025
2/26/2028
Tank
Fiberglass Brine Filled Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
5/8/2023
Tank
Fiberglass Brine Filled Double Wall XERXES
Precision Test (Tank)
Pass
5/8/2023
Tank Number 3
Capacity:
10000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/28/2023
Abandoned Material:
Current Age:
2
Abandoned Date:
Install Date:
12/6/2022
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/18/2025
4/18/2026
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor
4/18/2025
4/18/2026
Overfill Prev Device
Overfill Alarm
5/8/2023
5/8/2026
Overfill Prev Device
Overfill Drop Tube Valve
5/8/2023
5/8/2026
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Spill Contain Device
Double Wall Spill Bucket
5/8/2023
5/8/2026
Tank
Fiberglass Brine Filled Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
5/8/2023
Tank
Fiberglass Brine Filled Double Wall XERXES
Precision Test (Tank)
Pass
5/8/2023
Tank Number 4
Capacity:
6000
Petroleum Use:
Product:
E85
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/28/2023
Abandoned Material:
Current Age:
2
Abandoned Date:
Install Date:
12/6/2022
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/18/2025
4/18/2026
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor
4/18/2025
4/18/2026
Overfill Prev Device
Overfill Alarm
5/8/2023
5/8/2026
Overfill Prev Device
Overfill Drop Tube Valve
5/8/2023
5/8/2026
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Spill Contain Device
Double Wall Spill Bucket
5/8/2023
5/8/2026
Tank
Fiberglass Brine Filled Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
5/8/2023
Tank
Fiberglass Brine Filled Double Wall XERXES
Precision Test (Tank)
Pass
5/8/2023
Tank Number 5
Capacity:
30000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/28/2023
Abandoned Material:
Current Age:
2
Abandoned Date:
Install Date:
12/15/2022
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/18/2025
4/18/2026
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor
4/18/2025
4/18/2026
Overfill Prev Device
Overfill Alarm
5/8/2023
5/8/2026
Overfill Prev Device
Overfill Drop Tube Valve
5/8/2023
5/8/2026
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Spill Contain Device
Double Wall Spill Bucket
5/8/2023
5/8/2026
Tank
Fiberglass Brine Filled Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
5/8/2023
Tank
Fiberglass Brine Filled Double Wall XERXES
Precision Test (Tank)
Pass
5/8/2023
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 11/12
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 13/14
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 15/16
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 17/18
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 19/20
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 21M
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 21S/22M
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 22S
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
5/8/2023
5/8/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
4/18/2025
4/18/2026
MFD
Motorfuel Dispensing Forms
Facility Number
Name
City
Received Date
Letter
2047467
Thornton's #348
Lockport
08/10/2022
Letter
Form