Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2047175
Status: Active
Facility Name: Lenny's Gas N Wash Route 6 and Gouger, LLC
Address: 3000 Maple Road Joliet, IL 60487
County: Will
Property Parcel: 15-08-05-300-016-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01997
Green Tag Issue Date: 7/31/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Lenny's Gas N Wash Route 6 and Gougar, LLC
Owner Address: 8200 W. 185th St., Ste. K Tinley Park, IL 60487
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 6/20/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/31/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037452 Lenny's Gas N Wash Route 6 and Gougar, LLC Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020253126 (Pending)    Issue Date: 11/21/2025    Expiration Date: 1/20/2026    View NOV Form

Tanks Violations
5 Line leak detection equipment in alarm or failed test, must repair or replace. - Failed testing on 8/18/2025.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/2/2021 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/27/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/2021

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/18/2025 8/18/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/18/2025 8/18/2026
Overfill Prev Device Overfill Drop Tube Valve 9/9/2024 9/9/2027
Overfill Prev Device Overfill Drop Tube Valve 9/9/2024 9/9/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026
Spill Contain Device Double Wall Spill Bucket 9/9/2024 9/9/2027
Spill Contain Device Double Wall Spill Bucket 9/9/2024 9/9/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/8/2021
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 12/8/2021



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/2/2021 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/27/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/2021

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/18/2025 8/18/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/18/2025 8/18/2026
Overfill Prev Device Overfill Drop Tube Valve 9/9/2024 9/9/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026
Spill Contain Device Double Wall Spill Bucket 9/9/2024 9/9/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/8/2021
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 12/8/2021



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/2/2021 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/25/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/2021

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/18/2025 8/18/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/18/2025 8/18/2026
Overfill Prev Device Overfill Drop Tube Valve 9/9/2024 9/9/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026
Spill Contain Device Double Wall Spill Bucket 9/26/2024 9/26/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/8/2021
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 12/8/2021



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/2/2021 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/27/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/2021

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/18/2025 8/18/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/18/2025 8/18/2026
Overfill Prev Device Overfill Drop Tube Valve 9/9/2024 9/9/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026
Spill Contain Device Double Wall Spill Bucket 9/26/2024 9/26/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/8/2021
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 12/8/2021



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/2/2021 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/27/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/2021

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/9/2024 8/18/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/18/2025 8/18/2026
Overfill Prev Device Overfill Drop Tube Valve 9/15/2025 9/15/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026
Spill Contain Device Double Wall Spill Bucket 9/9/2024 9/9/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/8/2021
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 12/8/2021



Tank Number 6

Capacity: 3000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/25/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 19M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 19S/20M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 20S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/24/2024 9/24/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/18/2025 8/18/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2047175 Lenny's Gas N Wash Route 6 and Gouger, LLC Joliet 11/21/2024 Letter Form
2047175 Lenny's Gas N Wash Route 6 and Gouger, LLC Joliet 12/07/2021 Letter Form