Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2047102
Status: Active
Facility Name: Woodman's Unattended Fuel Station
Address: 7 Stratford Drive Bloomingdale, IL 60108
County: Du Page
Property Parcel: 02-17-400-099
Facility Type: Unattended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003824
Green Tag Issue Date: 5/10/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Woodman's Food Market, Inc.
Owner Address: 2631 Liberty Lane Janesville, WI 535450741
Owner Status: Current Owner
Purchase Date: 7/1/2019
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/29/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Unattended Self Service 5/10/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030284 Woodman's Food Market, Inc. Current Owner 7/1/2019

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252433 (Pending)    Issue Date: 9/17/2025    Expiration Date: 11/16/2025    View NOV Form

Tanks Violations
Facility Annual Fire Detection Test has not been performed - 2) The fire alarm system shall be installed, tested and maintained according to NFPA 70 and NFPA 72. The alarm system must also meet the alarm system requirements of subsections (h)(1)(C) and (h)(2)(D), including the requirement for an audible alarm when triggered.

NOV Number: E0020252434 (Pending)    Issue Date: 9/17/2025    Expiration Date: 11/16/2025    View NOV Form

Tanks Violations
Facility Miscellaneous - Emergency shut off switch next to overfill alarm needs a sign. 175.210 d) 3) Equipped with an emergency stop at all control stations, which shall be conspicuously marked and readily accessible to the attendant, whether or not the control station is less than 20 feet from any dispenser or a security booth is provided for the attendant. The emergency stop shall be located in a position to allow all dispensing devices to be readily visible to the attendant, or as approved by OSFM. Each emergency stop shall be identified by a sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/5/2021 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 10/8/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/29/2021

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/25/2025 2/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 2/25/2025 2/25/2026
Overfill Prev Device Overfill Alarm 3/28/2024 3/28/2027
Overfill Prev Device Overfill Drop Tube Valve 3/28/2024 3/28/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 2/25/2025 2/25/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/25/2025 2/25/2026
Spill Contain Device Single Wall Spill Bucket 3/28/2024 3/28/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 2/25/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/21/2023



Tank Number 2

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/5/2021 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 10/8/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/29/2021

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/25/2025 2/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 2/25/2025 2/25/2026
Overfill Prev Device Overfill Alarm 3/28/2024 3/28/2027
Overfill Prev Device Overfill Drop Tube Valve 3/28/2024 3/28/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 2/25/2025 2/25/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/25/2025 2/25/2026
Spill Contain Device Single Wall Spill Bucket 3/28/2024 3/28/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 2/25/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/21/2023



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/5/2021 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 10/8/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/29/2021

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/25/2025 2/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 2/25/2025 2/25/2026
Overfill Prev Device Overfill Alarm 3/28/2024 3/28/2027
Overfill Prev Device Overfill Drop Tube Valve 3/28/2024 3/28/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 2/25/2025 2/25/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/25/2025 2/25/2026
Spill Contain Device Single Wall Spill Bucket 3/28/2024 3/28/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 2/25/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/21/2023

Dispenser Information



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/25/2025 2/25/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/25/2025 2/25/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/25/2025 2/25/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/25/2025 2/25/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/25/2025 2/25/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/25/2025 2/25/2026



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/25/2025 2/25/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/25/2025 2/25/2026



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/25/2025 2/25/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/25/2025 2/25/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2047102 Woodman's Unattended Fuel Station Bloomingdale 08/02/2021 Letter Form