Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0041939 |
SBR 1445 Oakton Street, LLC |
Current Owner |
6/25/2026 |
| U0041684 |
B TP IOS Elk Grove Village LLC |
Former Owner |
7/10/2025 |
| U0041050 |
Asphalt, Builders |
Former Owner |
11/1/2023 |
| U0039185 |
Arrow Road Construction |
Former Owner |
6/6/2018 |
Notice of Violations (Current)
NOV Number:
E0020262322
(Pending)
Issue Date:
10/2/2026
Expiration Date:
12/1/2026
View NOV Form
| Tanks |
Violations |
| 1, 2, 3 |
Submit Notification Form For OOS Tank Status Change - The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm |
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
5000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Out of service |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/23/2018 |
|
Abandoned Material: |
|
| Current Age: |
8 |
|
Abandoned Date: |
|
| Install Date: |
6/7/2018 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
12/31/2025 |
|
Fee Due: |
$0.00 |
| Product Date: |
6/7/2018 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
12/31/2025 |
12/31/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
12/31/2025 |
12/31/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
12/31/2025 |
12/31/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
7/18/2024 |
7/18/2027 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
7/18/2024 |
7/18/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
7/18/2024 |
7/18/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
7/18/2024 |
7/18/2027 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
6000 |
|
Petroleum Use: |
Dispensing |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Out of service |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/23/2018 |
|
Abandoned Material: |
|
| Current Age: |
8 |
|
Abandoned Date: |
|
| Install Date: |
6/7/2018 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
12/31/2025 |
|
Fee Due: |
$0.00 |
| Product Date: |
6/7/2018 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
2/12/2026 |
2/12/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
12/31/2025 |
12/31/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
12/31/2025 |
12/31/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
7/18/2024 |
7/18/2027 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
7/18/2024 |
7/18/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
7/18/2024 |
7/18/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
7/18/2024 |
7/18/2027 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
5000 |
|
Petroleum Use: |
Dispensing |
| Product: |
Dyed Diesel |
|
CERCLA Substance: |
|
| Status: |
Out of service |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/23/2018 |
|
Abandoned Material: |
|
| Current Age: |
8 |
|
Abandoned Date: |
|
| Install Date: |
6/7/2018 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
12/31/2025 |
|
Fee Due: |
$0.00 |
| Product Date: |
6/7/2018 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
2/12/2026 |
2/12/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD |
12/31/2025 |
12/31/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
12/31/2025 |
12/31/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
7/18/2024 |
7/18/2027 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
7/18/2024 |
7/18/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
7/18/2024 |
7/18/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
7/18/2024 |
7/18/2027 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/2
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
7/18/2024
|
7/18/2027
|
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
12/31/2025
|
12/31/2026
|
Name\ID 3/4
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
7/18/2024
|
7/18/2027
|
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
12/31/2025
|
12/31/2026
|
Name\ID 5/6
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
7/18/2024
|
7/18/2027
|
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
12/31/2025
|
12/31/2026
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found