Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046320
Status: Active
Facility Name: Old Dominion Freight Line, Inc.
Address: 2150 Aucutt Road Montgomery, IL 60538
County: Kane
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Y003810
Green Tag Issue Date: 9/20/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Old Dominion Freight Line, Inc.
Owner Address: 500 Old Dominion Way Thomasville, NC 27360
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 9/20/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0027099 Old Dominion Freight Line, Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251543 (Pending)    Issue Date: 6/17/2025    Expiration Date: 8/16/2025    View NOV Form

Tanks Violations
1 Tank interstitial sensors in alarm or failed test, must repair or replace. - Repair or replace sensor and retest. Passing results shall be entered on OSFM portal

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/20/2017 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 4/19/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/17/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/4/2025 4/4/2026
Leak Detect - Tank Automatic Tank Gauging 4/4/2025 4/4/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/30/2025 6/30/2026
Overfill Prev Device Overfill Alarm 4/4/2025 4/4/2028
Overfill Prev Device Overfill Drop Tube Valve 4/4/2025 4/4/2028
Piping Flexible Double Wall NUPI Smartflex N/A N/A
Piping Single Wall STP/Tanktop Sump 6/21/2024 6/21/2027
Leak Detect - Piping Sump Sensor with positive shutdown 4/4/2025 4/4/2026
Piping Single Wall STP/Tanktop Sump 6/21/2024 6/21/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/5/2023 4/12/2024
Leak Detect - Piping Sump Sensor with positive shutdown 4/4/2025 4/4/2026
Piping Single Wall STP/Tanktop Sump 6/21/2024 6/21/2027
Leak Detect - Piping Sump Sensor with positive shutdown 4/4/2025 4/4/2026
Piping Single Wall STP/Tanktop Sump 6/21/2024 6/21/2027
Leak Detect - Piping Sump Sensor with positive shutdown 4/4/2025 4/4/2026
Piping Single Wall Transition Sump 6/21/2024 6/21/2027
Leak Detect - Piping Sump Sensor with positive shutdown 4/4/2025 4/4/2026
Spill Contain Device Single Wall Spill Bucket Horizontal Cabinet 4/4/2025 4/4/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 4/4/2025



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 9/20/2017 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 4/19/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/17/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/24/2017 8/24/2018
Overfill Prev Device Overfill Alarm
Piping Flexible Double Wall NUPI Smartflex N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/21/2024 6/21/2027
Leak Detect - Piping Sump Sensor with positive shutdown 4/4/2025 4/4/2026



Name\ID 1 Satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/21/2024 6/21/2027
Leak Detect - Piping Sump Sensor with positive shutdown 4/4/2025 4/4/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2046320 Old Dominion Freight Line, Inc. Montgomery 05/16/2017 Letter Form