Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
20000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
9/4/2019 |
|
Abandoned Material: |
|
| Current Age: |
8 |
|
Abandoned Date: |
|
| Install Date: |
1/13/2017 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/29/2018 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
12/22/2025 |
12/22/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
12/22/2025 |
12/22/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
2/27/2025 |
2/27/2028 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
2/27/2025 |
2/27/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
2/27/2025 |
2/27/2028 |
|
Piping
|
Ball Valves |
Not applicable |
Not applicable |
|
Piping
|
Shear Valves |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
2/27/2025 |
2/27/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
2/15/2022
|
|
Tank
|
Fiberglass Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
2/15/2022
|
Tank Number 2
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
9/4/2019 |
|
Abandoned Material: |
|
| Current Age: |
8 |
|
Abandoned Date: |
|
| Install Date: |
1/13/2017 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/29/2018 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
12/22/2025 |
12/22/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
3/10/2026 |
3/10/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
2/27/2025 |
2/27/2028 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
2/27/2025 |
2/27/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
2/27/2025 |
2/27/2028 |
|
Piping
|
Ball Valves |
Not applicable |
Not applicable |
|
Piping
|
Shear Valves |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
2/27/2025 |
2/27/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
2/15/2022
|
|
Tank
|
Fiberglass Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
2/15/2022
|
Tank Number 3
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
9/4/2019 |
|
Abandoned Material: |
|
| Current Age: |
8 |
|
Abandoned Date: |
|
| Install Date: |
1/13/2017 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/29/2018 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
12/22/2025 |
12/22/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
12/22/2025 |
12/22/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
9/11/2025 |
9/11/2028 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
2/27/2025 |
2/27/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
2/27/2025 |
2/27/2028 |
|
Piping
|
Ball Valves |
Not applicable |
Not applicable |
|
Piping
|
Shear Valves |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
2/27/2025 |
2/27/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
2/15/2022
|
|
Tank
|
Fiberglass Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
2/15/2022
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
| Facility Number |
Name |
City |
Received Date |
Letter |
|
2046201
|
801 Bensenville IL, LLC
|
Bensenville
|
12/12/2017
|
Letter
Form
|