Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046192
Status: Active
Facility Name: Speedway #7412
Address: 1110 Irving Park Road Bensenville, IL 60106
County: Du Page
Property Parcel: 03-14-117-066
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000109
Green Tag Issue Date: 3/20/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Speedway, LLC
Owner Address: P.O. Box 1500 Springfield, OH 45501
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/8/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0026552 Speedway, LLC Current Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00007-2026UPG Upgrade Approved / Issued 1/2/2026 1/4/2026 7/7/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020260395 (Pending)    Issue Date: 2/19/2026    Expiration Date: 4/20/2026    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Dispenser 9/10, 17/18, and all truck side dispensers are not functioning. 175.210 h)The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom.

NOV Number: E0020260396 (Pending)    Issue Date: 2/19/2026    Expiration Date: 4/20/2026    View NOV Form

Tanks Violations
1, 2, 5 Dispensers - hoses cracked, split or worn and require replacement - Replace main hose. There's cracks at the bend.
6, 7 Drop tube valve or overfill alarm failed inspection. Repair or replace equipment. - Overfill drop tubes failed testing on 2/17/26. Repair or replace overfill drop tubes and retest. Passing results shall be entered on OSFM portal. Both east and the west drop tubes failed.
1, 2, 3, 4, 5, 6, 7 Line interstitial sensors have been raised and rendered inoperational. - All sensors in STP sumps are raised. Section 175.640 a)2) All new and existing sump sensors must be installed so as to detect liquid per manufacturer's specifications or, if not specified by the manufacturer, at the lowest point in the sump.
5 Miscellaneous - Probe or sensor well has a rusted apart support ring missing.
1, 2, 3, 4, 5, 6, 7 Piping interstitial must be open in all sumps - Check all STP sumps. 175.420 b) Unless otherwise required by the manufacturer, the dispenser product piping sump jumper tubes shall be removed, or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/9/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/21/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/27/2025 8/27/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/27/2025 8/27/2026
Overfill Prev Device Overfill Drop Tube Valve 2/17/2026 2/17/2029
Overfill Prev Device Overfill Drop Tube Valve 2/17/2026 2/17/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/27/2025 8/27/2026
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/10/2023



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/9/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/21/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/27/2025 8/27/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/27/2025 8/27/2026
Overfill Prev Device Overfill Drop Tube Valve 1/9/2026 1/9/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/27/2025 8/27/2026
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/9/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/21/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/27/2025 8/27/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/27/2025 8/27/2026
Overfill Prev Device Overfill Drop Tube Valve 1/9/2026 1/9/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/27/2025 8/27/2026
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/9/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/21/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/27/2025 8/27/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/27/2025 8/27/2026
Overfill Prev Device Overfill Drop Tube Valve 1/9/2026 1/9/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/27/2025 8/27/2026
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/9/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/21/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/27/2025 8/27/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/27/2025 8/27/2026
Overfill Prev Device Overfill Drop Tube Valve 1/9/2026 1/9/2029
Overfill Prev Device Overfill Drop Tube Valve 1/9/2026 1/9/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/27/2025 8/27/2026
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/10/2023



Tank Number 6

Capacity: 20000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/9/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/28/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/27/2025 8/27/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/27/2025 8/27/2026
Overfill Prev Device Overfill Drop Tube Valve 2/19/2026 2/19/2029
Overfill Prev Device Overfill Drop Tube Valve 2/19/2026 2/19/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/27/2025 8/27/2026
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/10/2023



Tank Number 7

Capacity: 20000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/9/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/28/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/27/2025 8/27/2026
Overfill Prev Device Overfill Drop Tube Valve 2/19/2026 2/19/2029
Overfill Prev Device Overfill Drop Tube Valve 2/19/2026 2/19/2029
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/27/2025 8/27/2026
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Spill Contain Device Double Wall Spill Bucket 2/10/2026 2/10/2029
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/10/2023



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 12/9/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/28/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Alarm
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping OmegaFlex DEF-Trac flexible stainless steel with heat trace N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 23/24

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 25

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 25/26

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 26/27

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 27

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 10/4/2025 10/4/2028
Leak Detect - Piping Sump Sensor 8/27/2025 8/27/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2046192 Speedway #7412 Bensenville 12/06/2016 Letter Form