Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046184
Status: Active
Facility Name: Murphy USA #7608
Address: 431 E Lincoln Hwy. New Lenox, IL 60451
County: Will
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: BB01708
Green Tag Issue Date: 5/7/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Self Service

Owner Details

Owner Name: Murphy Oil USA, Inc.
Owner Address: 200 E. Peach Street El Dorado, AR 71730
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0029289 Murphy Oil USA, Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 25000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/27/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/22/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/12/2026 1/12/2027
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/12/2026 1/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 1/12/2026 1/12/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/12/2026 1/12/2027
Overfill Prev Device Overfill Drop Tube Valve 5/23/2024 5/23/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2025 3/13/2028
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 8/12/2020 8/12/2021
Leak Detect - Piping Sump Sensor with positive shutdown 1/12/2026 1/12/2027
Spill Contain Device Double Wall Spill Bucket 1/12/2026 1/12/2029
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 1/12/2026



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/27/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/22/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/12/2026 1/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 1/12/2026 1/12/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/12/2026 1/12/2027
Overfill Prev Device Overfill Drop Tube Valve 4/2/2024 4/2/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2025 3/13/2028
Leak Detect - Piping Sump Sensor with positive shutdown 1/12/2026 1/12/2027
Spill Contain Device Double Wall Spill Bucket 1/12/2026 1/12/2029
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 1/12/2026



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/27/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/22/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/12/2026 1/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 1/12/2026 1/12/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/12/2026 1/12/2027
Overfill Prev Device Overfill Drop Tube Valve 4/2/2024 4/2/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2025 3/13/2028
Leak Detect - Piping Sump Sensor with positive shutdown 1/12/2026 1/12/2027
Spill Contain Device Double Wall Spill Bucket 1/12/2026 1/12/2029
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 1/12/2026



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/27/2016 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 7/22/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/12/2026 1/12/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 1/12/2026 1/12/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/12/2026 1/12/2027
Overfill Prev Device Overfill Drop Tube Valve 4/2/2024 4/2/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2025 3/13/2028
Leak Detect - Piping Sump Sensor with positive shutdown 1/12/2026 1/12/2027
Spill Contain Device Double Wall Spill Bucket 1/12/2026 1/12/2029
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 1/12/2026

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2025 3/13/2028
Leak Detect - Piping Sump Sensor with positive shutdown 1/12/2026 1/12/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2025 3/13/2028
Leak Detect - Piping Sump Sensor with positive shutdown 1/12/2026 1/12/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2025 3/13/2028
Leak Detect - Piping Sump Sensor with positive shutdown 1/12/2026 1/12/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2025 3/13/2028
Leak Detect - Piping Sump Sensor with positive shutdown 1/12/2026 1/12/2027

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2046184 Murphy USA #7608 New Lenox 01/10/2017 Letter Form
2046184 Murphy USA #7608 New Lenox 08/23/2016 Letter Form
2046184 Murphy USA #7608 New Lenox 07/14/2016 Letter Form
2046184 Murphy USA #7608 New Lenox 08/23/2016 Form