Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046017
Status: Active
Facility Name: Pilot Travel Center #1042
Address: 7501 S. Harlem Bridgeview, IL 60455
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000607
Green Tag Issue Date: 11/25/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Pilot Travel Centers, LLC
Owner Address: 5508 Lonas Rd. Knoxville, TN 37909
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/18/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0011913 Pilot Travel Centers, LLC Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261230 (Pending)    Issue Date: 5/11/2026    Expiration Date: 7/10/2026    View NOV Form

Tanks Violations
1, 2, 3, 4, 5 Required monthly tank leak test records not available. - Please supply or have all tanks tightness tested
1, 2, 3, 4, 5, 6 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1, 2, 3, 4, 5, 6 Tank monitor does not appear to function properly and requires maintenance. - IN ALARM AND PRINTER NOT WORKING

NOV Number: E0020261231 (Pending)    Issue Date: 5/11/2026    Expiration Date: 7/10/2026    View NOV Form

Tanks Violations
Facility Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - PLEASE REPAIR CAMERA MONITORS AT THE COUNTER

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 16000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/2016 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 3/10/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/4/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/29/2025 10/29/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 10/29/2025 10/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/29/2025 10/29/2026
Overfill Prev Device Overfill Drop Tube Valve 1/10/2024 1/10/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Spill Contain Device Double Wall Spill Bucket 5/2/2025 5/2/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/29/2025
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 3/21/2018
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/7/2020



Tank Number 2

Capacity: 9000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/2016 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 3/10/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/4/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/31/2025 10/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 10/29/2025 10/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/29/2025 10/29/2026
Overfill Prev Device Overfill Drop Tube Valve 1/10/2024 1/10/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Spill Contain Device Double Wall Spill Bucket 5/2/2025 5/2/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/29/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/7/2020



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/2016 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 3/10/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/4/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/29/2025 10/29/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 10/29/2025 10/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/29/2025 10/29/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2024 2/21/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Spill Contain Device Double Wall Spill Bucket 5/2/2025 5/2/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/29/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/7/2020



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/2016 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 3/10/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/4/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/29/2025 10/29/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 10/29/2025 10/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/29/2025 10/29/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2024 2/21/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall Transition Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Spill Contain Device Double Wall Spill Bucket 5/2/2025 5/2/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/29/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/7/2020



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/2016 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 3/10/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/4/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/31/2025 10/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 10/29/2025 10/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/29/2025 10/29/2026
Overfill Prev Device Overfill Drop Tube Valve 6/3/2025 6/3/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Spill Contain Device Double Wall Spill Bucket 6/3/2025 6/3/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/29/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/7/2020



Tank Number 6

Capacity: 20000 Petroleum Use: None
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/28/2016 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 3/10/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/29/2025 10/29/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 10/29/2025 10/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/29/2025 10/29/2026
Overfill Prev Device Overfill Drop Tube Valve 6/3/2025 6/3/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall Transition Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Spill Contain Device Double Wall Spill Bucket 6/3/2025 6/3/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/10/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/7/2020



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 4/28/2016 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 3/10/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Spill Contain Device Double Wall Spill Bucket
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 17

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 18/19

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 20/21

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 22/23

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 23

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2023 6/9/2026
Leak Detect - Piping Sump Sensor 10/29/2025 10/29/2026

MFD Motorfuel Dispensing Forms