Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045606
Status: Active
Facility Name: Casey's General Store #3376
Address: 309 S. Division St. Harvard, IL 60033
County: McHenry
Property Parcel: 06-02-201-037
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001415
Green Tag Issue Date: 4/12/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave. P.O. Box 3004 Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date: 6/26/2014
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 1/29/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner 6/26/2014

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261229 (Pending)    Issue Date: 5/8/2026    Expiration Date: 7/7/2026    View NOV Form

Tanks Violations
Facility Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - Section 175.210g; All dispensing units shall be readily visible from the control station without assistive devices. If view is permanently obstructed, or the dispenser is located so that activity is not readily visible, closed-circuit cameras that provide a view of each side of the dispensing unit and project an image on a screen at least 6 inches in diagonal located at the control station may be used. You may also elect to install an emergency stop switch at least 20 feet but no more than 50 feet from any dispenser with a permanently obstructed view.
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 18000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/29/2014 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 6/26/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 10/2/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/23/2025 7/23/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/23/2025 7/23/2026
Overfill Prev Device Overfill Drop Tube Valve 8/3/2023 8/3/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 8/3/2023 8/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Spill Contain Device Single Wall Spill Bucket 8/3/2023 8/3/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/29/2014 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 6/26/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 10/2/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/23/2025 7/23/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/23/2025 7/23/2026
Overfill Prev Device Overfill Drop Tube Valve 8/3/2023 8/3/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 8/3/2023 8/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Spill Contain Device Single Wall Spill Bucket 8/3/2023 8/3/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/29/2014 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 6/26/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 10/2/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/23/2025 7/23/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/23/2025 7/23/2026
Overfill Prev Device Overfill Drop Tube Valve 8/3/2023 8/3/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 8/3/2023 8/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Spill Contain Device Single Wall Spill Bucket 8/3/2023 8/3/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/29/2014 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 6/26/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 10/2/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/23/2025 7/23/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/23/2025 7/23/2026
Overfill Prev Device Overfill Drop Tube Valve 8/3/2023 8/3/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 8/3/2023 8/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Spill Contain Device Single Wall Spill Bucket 8/3/2023 8/3/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 3/5/2021

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/3/2023 8/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/3/2023 8/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/3/2023 8/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/3/2023 8/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/3/2023 8/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/3/2023 8/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026

MFD Motorfuel Dispensing Forms

No Forms Found