Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045418
Status: Active
Facility Name: AMITA Outpatient Pavilion
Address: 331 W. Surf St. Chicago, IL 60657
County: Cook
Property Parcel: 14-28-206-006-0000
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: BB04426
Green Tag Issue Date: 6/23/2026
Green Tag Expire Date: 12/31/2028
MFD Type: N/A

Owner Details

Owner Name: Chicago 331 APL RKC, LLC
Owner Address: 800 W. Madison Street Suite 400 Chicago, IL 60607
Owner Status: Current Owner
Purchase Date: 12/30/2020
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/23/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040329 Chicago 331 APL RKC, LLC Current Owner 12/30/2020
U0038728 HP Saint Joseph ACC, LLC Former Owner 8/15/2016
U0036944 Robert Bearlund / Hammes Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/13/2016 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 5/28/2015 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping American with Sensors/No Test Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 12/9/2025 12/9/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/9/2025 12/9/2026
Overfill Prev Device Overfill Drop Tube Valve 5/17/2024 5/17/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 5/17/2024 5/17/2027
Leak Detect - Piping Sump Sensor 5/17/2024 5/17/2027
Piping Single Wall STP/Tanktop Sump 5/17/2024 5/17/2027
Leak Detect - Piping Sump Sensor 5/17/2024 5/17/2027
Piping Single Wall Transition Sump 5/17/2024 5/17/2027
Leak Detect - Piping Sump Sensor 5/17/2024 5/17/2027
Spill Contain Device Single Wall Spill Bucket 5/17/2024 5/17/2027
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Sensors/No Test Suction Functional Pass 12/9/2025



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Entered in error CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms