Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2044196
Status: Active
Facility Name: UNFI Wholesale, Inc.
Address: 2600 Haven W. Joliet, IL 60433
County: Will
Property Parcel: 15-08-19-101-009-0000
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Y003706
Green Tag Issue Date: 1/3/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: SV Distribution Joliet Illinois, LLC
Owner Address: 313 Iron Horse Way Providence, RI 02908
Owner Status: Current Owner
Purchase Date: 10/23/2018
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/14/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 1/3/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041173 SV Distribution Joliet Illinois, LLC Current Owner 10/23/2018
U0038904 SuperValu Holdings, Inc. Former Owner 9/14/2017
U0034995 Central Grocers Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251821 (Pending)    Issue Date: 7/15/2025    Expiration Date: 9/13/2025    View NOV Form

Tanks Violations
1, 2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP handles are broken on both lids and need to be repaired or rep[laced.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 25000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/10/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 12/4/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/5/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/30/2024 9/30/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 9/30/2024 9/30/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/30/2024 9/30/2025
Overfill Prev Device Overfill Drop Tube Valve 10/3/2024 10/3/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/20/2022 10/20/2025
Leak Detect - Piping Sump Sensor 9/30/2024 9/30/2025
Spill Contain Device Single Wall Spill Bucket 9/12/2022 9/12/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/30/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Dyed Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/10/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 12/4/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/5/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/30/2024 9/30/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 9/30/2024 9/30/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/30/2024 9/30/2025
Overfill Prev Device Overfill Drop Tube Valve 10/3/2024 10/3/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/20/2022 10/20/2025
Leak Detect - Piping Sump Sensor 9/30/2024 9/30/2025
Spill Contain Device Single Wall Spill Bucket 9/12/2022 9/12/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/30/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/12/2022 9/12/2025
Leak Detect - Piping Sump Sensor 9/30/2024 9/30/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/12/2022 9/12/2025
Leak Detect - Piping Sump Sensor 9/30/2024 9/30/2025

MFD Motorfuel Dispensing Forms

No Forms Found