Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2043134
Status: Active
Facility Name: Brake Time
Address: 3195 E. Division Street Diamond, IL 60416
County: Grundy
Property Parcel: 02-24-06-200-017
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000183
Green Tag Issue Date: 9/4/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Brake Time IL Properties, LLC
Owner Address: 6300 Richmond Avenue, Suite 300 Houston, TX 77057
Owner Status: Current Owner
Purchase Date: 11/8/2024
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/27/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041353 Brake Time IL Properties, LLC Current Owner 11/8/2024
U0039389 Minit Mart, LLC Former Owner 12/5/2018
U0026726 TA Operating, LLC Former Owner 2/25/2016
U0033239 B.P. Markets, Inc. Former Owner 3/7/2006

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020260905 (Pending)    Issue Date: 4/6/2026    Expiration Date: 6/5/2026    View NOV Form

Tanks Violations
1, 2, 3, 4, 7 Annual electronic line leak detector test not completed. - Line leak detectors need annual testing. Testing shall be performed and passing results entered on OSFM portal.
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shut off switch needs annual testing performed. OSFM form shall be kept on site.
1, 2, 3, 4, 7 Annual leak detection certification not completed (Required annually). - Annual leak detection testing shall be performed and passing results entered on OSFM portal.
1, 2, 3, 4, 7 Document that emergency shut-off (shear valves) are in proper working order - Shear valves need annual testing performed. OSFM form shall be completed and kept on site.
2 Drop tube valve or overfill alarm failed inspection. Repair or replace equipment. - Repair or replace drop tube and enter passing test results on OSFM portal. Overfill drop tube failed testing on 3/26/25.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual walkthrough needs to be performed. OSFM form shall be completed and kept on site.
1, 2, 3, 4, 7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - 175.405 a) 1) A) Spill containment equipment that will prevent release of product to the environment when the transfer hose is detached from the fill pipe (e.g., a spill catch basin). Spill containment equipment shall be maintained in a dry, clean state.
2 Tank monitor does not appear to function properly and requires maintenance. - T2 premium is not showing on ATG CSLD tank test for April. Repair so all tanks are doing CSLD tank tests. If ATG does not run a CSLD tank test for April and May a precision tank test will be required.
1 Water in containment without required interstitial sensors - install cathodic protection on all exposed steel. - There is water in regular STP sump. Water can be removed and sump repaired. If cathodic protection is installed it shall be removed and sump repaired to be water tight on 10/13/28.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2021-0538 1/10/2022 Abandonment Log 01436-2021ABN

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/28/2006 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 4/7/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/10/2026 4/10/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/10/2026 4/10/2027
Overfill Prev Device Overfill Drop Tube Valve 3/26/2025 3/26/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/10/2026 4/10/2029
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/26/2025 3/26/2028
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 4/18/2024
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 8/27/2020



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/28/2006 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 4/7/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/10/2026 4/10/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/10/2026 4/10/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 4/10/2026 4/10/2029
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/26/2025 3/26/2028
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 4/18/2024
Tank Fiberglass Single Wall Containment Solutions Precision Test (Tank) Pass 1/12/2020
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 8/27/2020



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/28/2006 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 4/7/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/10/2026 4/10/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/10/2026 4/10/2027
Overfill Prev Device Overfill Drop Tube Valve 3/26/2025 3/26/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/26/2025 3/26/2028
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 4/18/2024
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 8/27/2020



Tank Number 4

Capacity: 7000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/28/2006 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 4/7/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/10/2026 4/10/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/10/2026 4/10/2027
Overfill Prev Device Overfill Drop Tube Valve 3/26/2025 3/26/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/26/2025 3/26/2028
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 4/18/2024
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 8/27/2020



Tank Number 5

Capacity: 7000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/28/2006 Abandoned Material: Tripolymer Foam
Current Age: 20 Abandoned Date: 1/10/2022
Install Date: 4/7/2006 Red Tag Issue Date:
Last Used Date: 2/1/2016 Fee Due: $0.00
Product Date: 4/7/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/15/2015 7/15/2016
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 8/27/2020 8/27/2021
Overfill Prev Device Ball Float Vent Valve EBW 308
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/19/2020 8/19/2023
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 4000 Petroleum Use:
Product: Racing Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/28/2006 Abandoned Material: Tripolymer Foam
Current Age: 20 Abandoned Date: 1/10/2022
Install Date: 4/7/2006 Red Tag Issue Date:
Last Used Date: 1/1/2019 Fee Due: $0.00
Product Date: 4/7/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/5/2019 8/5/2020
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/27/2020 8/27/2021
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D
Overfill Prev Device Ball Float Vent Valve EBW 308
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/5/2019 8/5/2022
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 8/27/2020
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 8/5/2019



Tank Number 7

Capacity: 4000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/28/2006 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 4/7/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/10/2026 4/10/2027
Overfill Prev Device Overfill Drop Tube Valve 3/26/2025 3/26/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket Insert 3/26/2025 3/26/2028
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 8/27/2020

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 11

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 13

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found