Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2041761
Status:
Active
Facility Name:
Woodman's Gas/Lube and Car Wash
Address:
2170 Randall Road
Carpentersville, IL 60110
County:
Kane
Property Parcel:
03-18-277-016
Facility Type:
Attended Self-Service/Unattended Self-Service
Owner Type:
Private
Green Tag Decal:
AA01220
Green Tag Issue Date:
4/17/2025
Green Tag Expiration Date:
12/31/2027
Owner Details
Owner Name:
Woodman's Food Market, Inc.
Owner Address:
2631 Liberty Lane
Janesville, WI 535450741
Owner Status:
Current Owner
Purchase Date:
9/22/2003
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
3/27/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Unattended Self Service
4/17/2025
12/31/2027
Self Service
4/18/2023
12/31/2025
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0030284
Woodman's Food Market, Inc.
Current Owner
9/22/2003
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
00195-2025UPG
Upgrade
Approved / Issued
2/19/2025
2/21/2025
8/21/2025
Documents
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/11/2004
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
9/22/2003
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
2/25/2004
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
1/9/2025
1/9/2026
Leak Detect - Tank
Automatic Tank Gauging Franklin Fueling Systems EVO 600
1/9/2025
1/9/2026
Overfill Prev Device
Overfill Alarm
1/9/2025
1/9/2028
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
6/6/2022
6/6/2025
Leak Detect - Piping
Sump Sensor
1/23/2024
1/23/2025
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Spill Contain Device
Single Wall Spill Bucket
6/6/2022
6/6/2025
Tank
Fiberglass Single Wall Containment Solutions
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
1/9/2025
Tank Number 2
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/11/2004
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
9/22/2003
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
2/25/2004
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
1/9/2025
1/9/2026
Leak Detect - Tank
Automatic Tank Gauging Franklin Fueling Systems EVO 600
1/9/2025
1/9/2026
Overfill Prev Device
Overfill Alarm
1/9/2025
1/9/2028
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
6/6/2022
6/6/2025
Leak Detect - Piping
Sump Sensor
1/23/2024
1/23/2025
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Spill Contain Device
Single Wall Spill Bucket
6/6/2022
6/6/2025
Tank
Fiberglass Single Wall Containment Solutions
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
1/9/2025
Tank Number 3
Capacity:
6000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/11/2004
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
9/22/2003
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
2/25/2004
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
1/9/2025
1/9/2026
Leak Detect - Tank
Automatic Tank Gauging Franklin Fueling Systems EVO 600
1/9/2025
1/9/2026
Overfill Prev Device
Overfill Alarm
1/9/2025
1/9/2028
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
6/6/2022
6/6/2025
Leak Detect - Piping
Sump Sensor
1/23/2024
1/23/2025
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Spill Contain Device
Single Wall Spill Bucket
6/6/2022
6/6/2025
Tank
Fiberglass Single Wall Containment Solutions
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
1/9/2025
Tank Number 4
Capacity:
20000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
10/2/2015
Abandoned Material:
Current Age:
9
Abandoned Date:
Install Date:
8/20/2015
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/20/2015
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
1/9/2025
1/9/2026
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550
1/9/2025
1/9/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
1/9/2025
1/9/2026
Overfill Prev Device
Overfill Alarm
1/10/2025
1/10/2028
Overfill Prev Device
Overfill Drop Tube Valve
1/9/2025
1/9/2028
Piping
Flexible Double Wall IPP
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
6/6/2022
6/6/2025
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Spill Contain Device
Single Wall Spill Bucket
6/6/2022
6/6/2025
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall IPP
Precision Test (Piping)
Pass
1/9/2025
Tank Number 5
Capacity:
4000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
10/2/2015
Abandoned Material:
Current Age:
9
Abandoned Date:
Install Date:
8/20/2015
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/20/2015
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
1/9/2025
1/9/2026
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550
1/9/2025
1/9/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
1/9/2025
1/9/2026
Overfill Prev Device
Overfill Alarm
1/10/2025
1/10/2028
Overfill Prev Device
Overfill Drop Tube Valve
1/9/2025
1/9/2028
Piping
Flexible Double Wall IPP
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
6/6/2022
6/6/2025
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Spill Contain Device
Single Wall Spill Bucket
6/6/2022
6/6/2025
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall IPP
Precision Test (Piping)
Pass
1/9/2025
Tank Number 6
Capacity:
30000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/15/2023
Abandoned Material:
Current Age:
1
Abandoned Date:
Install Date:
8/10/2023
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/27/2023
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
1/9/2025
1/9/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors With Monitor
1/9/2025
1/9/2026
Overfill Prev Device
Overfill Alarm
9/13/2023
9/13/2026
Overfill Prev Device
Overfill Drop Tube Valve
9/13/2023
9/13/2026
Piping
Flexible Double Wall Franklin Fueling Systems UPP
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Spill Contain Device
Double Wall Spill Bucket
9/13/2023
9/13/2026
Tank
Fiberglass Double Wall KBK Industries
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Franklin Fueling Systems UPP
Precision Test (Piping)
Pass
12/21/2023
Tank
Fiberglass Double Wall KBK Industries
Precision Test (Tank)
Pass
12/21/2023
Tank Number 7
Capacity:
6000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/15/2023
Abandoned Material:
Current Age:
1
Abandoned Date:
Install Date:
8/10/2023
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/27/2023
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
1/9/2025
1/9/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors With Monitor
1/9/2025
1/9/2026
Overfill Prev Device
Overfill Alarm
9/13/2023
9/13/2026
Overfill Prev Device
Overfill Drop Tube Valve
9/13/2023
9/13/2026
Piping
Flexible Double Wall Franklin Fueling Systems UPP
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Spill Contain Device
Double Wall Spill Bucket
9/13/2023
9/13/2026
Tank
Composite Double Wall Lannon
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Franklin Fueling Systems UPP
Precision Test (Piping)
Pass
12/21/2023
Tank
Composite Double Wall Lannon
Precision Test (Tank)
Pass
12/21/2023
Tank Number 8
Capacity:
6000
Petroleum Use:
Product:
E85
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/15/2023
Abandoned Material:
Current Age:
1
Abandoned Date:
Install Date:
8/10/2023
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/27/2023
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
1/9/2025
1/9/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors With Monitor
1/9/2025
1/9/2026
Overfill Prev Device
Overfill Alarm
9/13/2023
9/13/2026
Overfill Prev Device
Overfill Drop Tube Valve
9/13/2023
9/13/2026
Piping
Flexible Double Wall Franklin Fueling Systems UPP
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Spill Contain Device
Double Wall Spill Bucket
9/13/2023
9/13/2026
Tank
Composite Double Wall Lannon
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Franklin Fueling Systems UPP
Precision Test (Piping)
Pass
12/21/2023
Tank
Composite Double Wall Lannon
Precision Test (Tank)
Pass
12/21/2023
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 11
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 13/14
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Name\ID 15/16
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Name\ID 17/18
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Name\ID 19/20
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Name\ID 21/22
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 31/32
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Name\ID 33/34
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Name\ID 35/36
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Name\ID 37/38
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Name\ID 39/40
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Sump Sensor with positive shutdown
1/9/2025
1/9/2026
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/13/2023
9/13/2026
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
Facility Number
Name
City
Received Date
Letter
2041761
Woodman's Gas/Lube and Car Wash
Carpentersville
07/02/2023
Letter
Form