Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2040347
Status: Active
Facility Name: Meijer Gas & C Store # 183
Address: 801 S. Randall Road
Elgin, IL 60123
County: Kane
Property Parcel: 06-28-127-073
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001654
Green Tag Issue Date: 1/17/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Meijer Great Lakes Limited Partnership
Owner Address: 2929 Walker Avenue, NW
Grand Rapids, MI 495449428
Owner Status: Current Owner
Purchase Date: 5/3/2001
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 8/1/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/17/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0023695 Meijer Great Lakes Limited Partnership Current Owner 5/3/2001

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00253-2025UPG Upgrade Approved / Issued 3/4/2025 3/4/2025 9/4/2025 Documents

Notice of Violations (Current)

NOV Number: E0020250675 (Pending)    Issue Date: 3/14/2025    Expiration Date: 5/13/2025    View NOV Form

Tanks Violation
Facility Code complying instruction/warning signs are not properly mounted at each dispenser island - Self-service instructional signs at dispensers are missing or do not meet minimum requirements. Install appropriate signage. MISSING SIGNS AT DISPENSERS #10, & 11/12 BOTH SIDES.
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.
Facility Remove brush, debris, wood chips or mulch located within 10' of dispensers - Remove combustible materials from the area of the listed dispenser(s).

NOV Number: E0020250676 (Pending)    Issue Date: 3/14/2025    Expiration Date: 5/13/2025    View NOV Form

Tanks Violation
2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Section 175.410 Submersible, Under-dispenser, Transition and Other Containment Sumps a) All containment sumps must consist of a factory manufactured containment that is liquid-tight on its sides, bottom and at any penetrations and is compatible with the substance conveyed by the piping. Such containment shall also have a factory manufactured protective cover and supporting components that are properly maintained. If the protective cover or its supporting components are cracked, deteriorated or missing, the cover and supporting components that are defective shall be replaced. SPECIFICALLY THE NORTH REGULAR STP LID IS MISSING THE HANDLE.
Facility Missing list of designated Class A/B & C Operators - A comprehensive list of Class A / B / C Operator(s) shall be maintained on site and must be current.
1, 2, 3, 4 Monthly line interstitial sensor records not available. - Maintain one NORMAL report per LINE, per month, from ATG. Must maintain 24 months’ worth.
1, 2, 3, 4 Precision tank test required. - Precision tank test is required on tank(s) if you cannot provide 24 months’ worth of tank “PASS” from ATG.
1, 2, 3, 4 Required monthly tank interstitial sensor records not available. - Maintain one NORMAL report per TANK, per month, from ATG. Must maintain 24 months’ worth.
4 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
4 Submit Notification Form For Tank Status Change - Submit OSFM Notification Form placing all tanks in Temporarily Out of Use status. The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. This form is required to be submitted within 30 days of a tank status change.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/24/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 5/3/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/30/2024 10/30/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/22/2024 10/22/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/3/2025 2/3/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 11/9/2023 11/9/2026
Overfill Prev Device Overfill Drop Tube Valve 11/9/2023 11/9/2026
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025
Spill Contain Device Single Wall Spill Bucket 12/18/2023 12/18/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/24/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 5/3/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/22/2024 10/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/22/2024 10/22/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/3/2025 2/3/2026
Overfill Prev Device Overfill Alarm 11/9/2023 11/9/2026
Overfill Prev Device Overfill Drop Tube Valve 11/9/2023 11/9/2026
Overfill Prev Device Overfill Drop Tube Valve 11/9/2023 11/9/2026
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025
Spill Contain Device Single Wall Spill Bucket 12/18/2023 12/18/2026
Spill Contain Device Single Wall Spill Bucket 12/18/2023 12/18/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/24/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 5/3/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/22/2024 10/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/22/2024 10/22/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/3/2025 2/3/2026
Overfill Prev Device Overfill Alarm 11/9/2023 11/9/2026
Overfill Prev Device Overfill Drop Tube Valve 11/9/2023 11/9/2026
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall Transition Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025
Spill Contain Device Single Wall Spill Bucket 12/18/2023 12/18/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 3000 Petroleum Use: None
Product: Ultra Low Sulfur Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/24/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 5/3/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/22/2024 10/22/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/22/2024 10/22/2025
Overfill Prev Device Overfill Alarm 11/9/2023 11/9/2026
Overfill Prev Device Overfill Drop Tube Valve 11/9/2023 11/9/2026
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025
Spill Contain Device Double Wall Spill Bucket 12/18/2023 12/18/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025



Name\ID 13

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/18/2023 12/18/2026
Leak Detect - Piping Sump Sensor 10/22/2024 10/22/2025

MFD Motorfuel Dispensing Forms

No Forms Found