Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2037440
Status: Active
Facility Name: Feece Oil Company
Address: 517 Twin Rail Drive Minooka, IL 60447
County: Grundy
Property Parcel: 03-02-427-008
Facility Type: Unattended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003373
Green Tag Issue Date: 12/19/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Feece Oil Company
Owner Address: 517 Twin Rail Drive Minooka, IL 60447
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 8/19/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Unattended Self Service 2/14/2023 12/31/2025
Self Service 7/24/2007 12/31/2009
Self Service 7/24/2007 12/31/2009

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0027734 Feece Oil Company Current Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00580-2025UPG Upgrade Approved / Amended 5/12/2025 5/12/2025 11/13/2025 Documents
00579-2025REM Removal Approved / Issued 5/12/2025 5/12/2025 11/13/2025 Documents

Notice of Violatlions (Current)

NOV Number: E0020252196 (Pending)    Issue Date: 8/25/2025    Expiration Date: 10/24/2025    View NOV Form

Tanks Violations
Facility Code complying instruction/warning signs are not properly mounted at each dispenser island - Dispenser 1 and 3 need a warning sign installed. The sign there can not be read.

NOV Number: E0020252197 (Pending)    Issue Date: 8/25/2025    Expiration Date: 10/24/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shut off switch needs annual testing performed. OSFM form shall be kept on site.
3 Dispensers - hose breakaways are missing or leaking - Hose is missing a breakaway. Install breakaway.
1, 2, 3, 4, 5 Document that emergency shut-off (shear valves) are in proper working order - Shear valves need annual testing performed. OSFM form shall be completed and kept on site.
4, 5 Line interstitial sensors have been raised and rendered inoperational. - Dispenser 1/2 has sensor raised. 175.640 a) 2) All new and existing sump sensors must be installed so as to detect liquid per manufacturer's specifications or, if not specified by the manufacturer, at the lowest point in the sump.
Facility Miscellaneous - A sign is required at each emergency shut off switch stating activation of the emergency stop "transmits a fire alarm to the fire department".
Facility Miscellaneous - Emergency shut off sign is required for shut off at dispenser 1.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual walkthrough needs to be performed. OSFM form shall be completed and kept on site.
3 Open electrical conduit or junction boxes. - Dispenser 5/6 has open electric. Two 90 caps are missing. Replace caps
5 Overfill prevention equipment does not appear to function properly. - Check overfill drop tube valve. It looks like the flap is down into the drop tube.
3, 4, 5 Piping interstitial must be open in all sumps - 175.420 b) Unless otherwise required by the manufacturer, the dispenser product piping sump jumper tubes shall be removed, or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. This is for all sumps.
1, 2, 3, 4, 5 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - 175.640 a) 2) All new and existing sump sensors must be installed so as to detect liquid per manufacturer's specifications or, if not specified by the manufacturer, at the lowest point in the sump.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20250421 Eligible 8/28/2025 8/29/2025 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 3/11/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/11/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/1/2023 11/1/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2024 10/4/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 10/4/2024 10/4/2025
Overfill Prev Device Overfill Drop Tube Valve 10/4/2024 10/4/2027
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/4/2024 10/4/2027
Tank Composite Single Wall Glasteel N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 10/4/2024



Tank Number 2

Capacity: 12000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: State Removed Date:
OSFM First Notify Date: 6/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 3/11/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/11/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/1/2023 11/1/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2024 10/4/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 10/4/2024 10/4/2025
Overfill Prev Device Overfill Drop Tube Valve 10/4/2024 10/4/2027
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/4/2024 10/4/2027
Tank Composite Single Wall Glasteel N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 10/4/2024



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 3/11/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/11/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/1/2023 11/1/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/9/2025 7/9/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 10/4/2024 10/4/2025
Overfill Prev Device Overfill Drop Tube Valve 6/13/2025 6/13/2028
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 6/17/2025 6/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/9/2025 7/9/2026
Spill Contain Device Double Wall Spill Bucket 6/17/2025 6/17/2028
Tank Composite Single Wall Glasteel N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 7/9/2025
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 10/4/2024



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 3/11/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/11/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/1/2023 11/1/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/9/2025 7/9/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 10/4/2024 10/4/2025
Overfill Prev Device Overfill Drop Tube Valve 6/13/2025 6/13/2028
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 6/17/2025 6/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/9/2025 7/9/2026
Spill Contain Device Double Wall Spill Bucket 6/17/2025 6/17/2028
Tank Composite Single Wall Glasteel N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 7/9/2025
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 10/4/2024



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 3/11/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/11/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/1/2023 11/1/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/9/2025 7/9/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 10/4/2024 10/4/2025
Overfill Prev Device Overfill Drop Tube Valve 8/29/2025 8/29/2028
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 6/17/2025 6/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/9/2025 7/9/2026
Spill Contain Device Double Wall Spill Bucket 6/17/2025 6/17/2028
Tank Composite Single Wall Glasteel N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 7/9/2025
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 10/4/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/17/2025 6/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/9/2025 7/9/2026



Name\ID 10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 2 Sat/ 5 Sat

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/17/2025 6/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/9/2025 7/9/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/17/2025 6/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/9/2025 7/9/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/17/2025 6/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/9/2025 7/9/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/17/2025 6/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/9/2025 7/9/2026



Name\ID 9

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found