Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2036054
Status: Active
Facility Name: Federal Express Station
Address: 1111 N Hooker Street
Chicago, IL 60610
County: Cook
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Z003935
Green Tag Issue Date: 2/29/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Federal Express Corporation
Owner Address: 3620 Hacks Cross Road, Bldg B, 3rd Floor
Memphis, TN 38125
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 11/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 2/29/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0018137 Federal Express Corporation Current Owner
U0005068 Federal Express Corp. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/1997 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 8/27/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/10/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/2/2023 10/2/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 10/2/2023 10/2/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/2/2023 10/2/2024
Overfill Prev Device Overfill Drop Tube Valve 12/3/2021 12/3/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 10/2/2019 10/2/2020
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/3/2021 12/3/2024
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/1997 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 8/27/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/10/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/2/2023 10/2/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 10/2/2023 10/2/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/2/2023 10/2/2024
Overfill Prev Device Overfill Drop Tube Valve 12/3/2021 12/3/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 10/2/2019 10/2/2020
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/3/2021 12/3/2024
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found