Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2035262
Status: Active
Facility Name: Thornton's #124
Address: 15918 S. Weber Road Lockport, IL 60441
County: Will
Property Parcel: 11-04-19-200-003-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA02001
Green Tag Issue Date: 8/29/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Thorntons, LLC
Owner Address: 2600 James Thornton Way Louisville, KY 40245
Owner Status: Current Owner
Purchase Date: 2/11/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/9/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039521 Thorntons, LLC Current Owner 2/11/2019
U0014995 Thornton's, Inc. - DO NOT USE THIS OWNER ID Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 10/22/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/22/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/27/2026 2/27/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 2/27/2026 2/27/2027
Overfill Prev Device Overfill Drop Tube Valve 3/12/2025 3/12/2028
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/8/2025 12/8/2028
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 10/20/2022



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 10/22/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/22/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/27/2026 2/27/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 2/27/2026 2/27/2027
Overfill Prev Device Overfill Drop Tube Valve 3/12/2025 3/12/2028
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Double Wall Spill Bucket 12/8/2025 12/8/2028
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 10/20/2022



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 10/22/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/22/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/27/2026 2/27/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 2/27/2026 2/27/2027
Overfill Prev Device Overfill Drop Tube Valve 3/12/2025 3/12/2028
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Double Wall Spill Bucket 12/8/2025 12/8/2028
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 10/20/2022



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 10/22/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/22/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/27/2026 2/27/2027
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 2/27/2026 2/27/2027
Overfill Prev Device Overfill Drop Tube Valve 3/12/2025 3/12/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 3/16/2023 3/16/2026
Leak Detect - Piping Sump Sensor 2/27/2026 2/27/2027
Piping Single Wall Transition Sump 12/8/2025 12/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown
Spill Contain Device Double Wall Spill Bucket 12/8/2025 12/8/2028
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 3/17/2022
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/20/2022
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 9/24/2019



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 10/22/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/22/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 2/27/2026 2/27/2027
Overfill Prev Device Overfill Drop Tube Valve 3/12/2025 3/12/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 12/8/2025 12/8/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/27/2026 2/27/2027
Spill Contain Device Double Wall Spill Bucket 12/8/2025 12/8/2028
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 4/6/2021
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/20/2022
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 9/24/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found