Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2034978
Status: Active
Facility Name: Amoco 13407
Address: 8800 W. Grand Ave. River Grove, IL 60171
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00086
Green Tag Issue Date: 10/31/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: RNG Fuels, Inc.
Owner Address: 8800 W. Grand Ave. River Grove, IL 60171
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 12/3/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037222 RNG Fuels, Inc. Current Owner
U0032360 Angel Associates, LP Former Owner 12/18/2009
U0027493 Amoco Oil Company Former Owner 7/1/1996
U0000552 BP Products North America, Inc. Former Owner 7/1/1996

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1996 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 7/24/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/24/1996

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/13/2026 6/13/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root EMC with CSLD 6/13/2026 6/13/2027
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 6/13/2026 6/13/2027
Overfill Prev Device Overfill Drop Tube Valve 12/1/2025 12/1/2028
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/11/2024 6/11/2027
Leak Detect - Piping Sump Sensor 6/11/2024 6/11/2027
Spill Contain Device Double Wall Spill Bucket 12/1/2025 12/1/2028
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable
Tank Fiberglass Brine Filled Double Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/11/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1996 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 7/24/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/24/1996

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/13/2026 6/13/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root EMC with CSLD 6/13/2026 6/13/2027
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 6/13/2026 6/13/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/11/2024 6/11/2027
Leak Detect - Piping Sump Sensor 6/11/2024 6/11/2027
Spill Contain Device Single Wall Spill Bucket 6/11/2024 6/11/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable
Tank Fiberglass Brine Filled Double Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/11/2024



Tank Number 3

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1996 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 7/24/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/24/1996

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/13/2026 6/13/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root EMC with CSLD 6/13/2026 6/13/2027
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 6/13/2026 6/13/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/11/2024 6/11/2027
Leak Detect - Piping Sump Sensor 6/11/2024 6/11/2027
Spill Contain Device Single Wall Spill Bucket 6/11/2024 6/11/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable
Tank Fiberglass Brine Filled Double Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/11/2024

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/11/2024 6/11/2027
Leak Detect - Piping Sump Sensor 6/13/2026 6/13/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/11/2024 6/11/2027
Leak Detect - Piping Sump Sensor 6/13/2026 6/13/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/11/2024 6/11/2027
Leak Detect - Piping Sump Sensor 6/13/2026 6/13/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/11/2024 6/11/2027
Leak Detect - Piping Sump Sensor 6/13/2026 6/13/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found