Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2034850
Status: Active
Facility Name: Bartlett Gasoline, Inc.
Address: 5590 County Farm Road Bartlett, IL 60103
County: Du Page
Property Parcel: 01-01-425-044
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002766
Green Tag Issue Date: 5/5/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Bartlett Real Properties, LLC
Owner Address: 5590 County Farm Road Bartlett, IL 60103
Owner Status: Current Owner
Purchase Date: 3/10/2020
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 4/23/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/5/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039836 Bartlett Real Properties, LLC Current Owner 3/10/2020
U0034433 HD Energy Corporation Former Owner 9/25/2007
U0027493 Amoco Oil Company Former Owner 7/31/1996
U0000552 BP Products North America, Inc. Former Owner 7/31/1996

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252608 (Pending)    Issue Date: 10/3/2025    Expiration Date: 12/2/2025    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - 175.210 h)The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom.

NOV Number: E0020252609 (Pending)    Issue Date: 10/3/2025    Expiration Date: 12/2/2025    View NOV Form

Tanks Violations
2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - T2 regular north STP sump lid needs to be repaired and or replaced so it can be opened. The handle is broken and it is wedged into the supporting rim.
1, 2, 3 Line interstitial sensors have been raised and rendered inoperational. - Dispenser 7/8 and T1 STP sump has a raised sensor. Lower sensors. Dispenser 5/6 and T2 has sensors lying down. Sensors shall be stood up.
Facility Miscellaneous - There is product in dispenser 7/8. The product needs to be removed.
1 Miscellaneous - ATG is reading 47 gallons .82" of water in tank.
1, 2, 3 Precision line test required. - Multiple times throughout the last 2 years different sensors have been in alarm. At this time two of the sensors have been raised and there is product in dispenser 7/8. A precision line test is needed to confirm there is no line leaks.
2 Tank interstitial sensors in alarm or failed test, must repair or replace. - ATG is in alarm L5 High Liquid Alarm. It has been in alarm multiple times over the last 2 years. This shall be repaired so ATG is clear of alarms.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/7/1997 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 7/31/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/31/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/24/2025 3/24/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 3/24/2025 3/24/2026
Overfill Prev Device Ball Float Vent Valve OPW 30MV 3/24/2025 3/24/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/7/2024 10/7/2027
Leak Detect - Piping Non-Discriminating Sump Sensor
Leak Detect - Piping Non-Discriminating Sump Sensor 5/6/2020 5/6/2021
Leak Detect - Piping Sump Sensor 3/14/2023 3/14/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/24/2025 3/24/2026
Spill Contain Device Single Wall Spill Bucket 10/7/2024 10/7/2027
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/24/2025
Tank Fiberglass Brine Filled Double Wall Precision Test (Tank) Pass 8/5/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 11/9/2006



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/7/1997 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 7/31/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/31/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/24/2025 3/24/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 3/24/2025 3/24/2026
Overfill Prev Device Ball Float Vent Valve OPW 30MV 3/24/2025 3/24/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor 3/24/2025 3/24/2026
Spill Contain Device Single Wall Spill Bucket 10/7/2024 10/7/2027
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/24/2025
Tank Fiberglass Brine Filled Double Wall Precision Test (Tank) Pass 8/5/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 11/9/2006



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/7/1997 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 7/31/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/31/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/24/2025 3/24/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 3/24/2025 3/24/2026
Overfill Prev Device Ball Float Vent Valve OPW 30MV 3/24/2025 3/24/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/7/2024 10/7/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 1/28/2020 5/6/2020
Leak Detect - Piping Sump Sensor 3/24/2025 3/24/2026
Spill Contain Device Single Wall Spill Bucket 10/7/2024 10/7/2027
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/24/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 11/9/2006

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor 3/24/2025 3/24/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor 3/24/2025 3/24/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor 3/24/2025 3/24/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor 3/24/2025 3/24/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor 3/24/2025 3/24/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/7/2024 10/7/2027
Leak Detect - Piping Sump Sensor 3/24/2025 3/24/2026

MFD Motorfuel Dispensing Forms

No Forms Found