Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2032174
Status: Active
Facility Name: Bolingbrook Fuel & Mini Mart
Address: 102 W. Boughton Rd. Bolingbrook, IL 60440
County: Will
Property Parcel: 12-02-10-219-031-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001643
Green Tag Issue Date: 10/2/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Bolingbrook Group, LLC
Owner Address: 205 N. Michigan #850 Chicago, IL 60601
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/25/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038290 Bolingbrook Group, LLC Current Owner
U0035809 Bolingbrook Commons Shopping Center Group Former Owner
U0007404 Illinois Petroleum Company, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261016 (Pending)    Issue Date: 4/16/2026    Expiration Date: 6/15/2026    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Form available at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Facility Operation and Maintenance Plan not completed or available. - Form available at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Missing copies of 30 day Walkthrough Inspection Report. - Form available at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Missing copies of Annual Walkthrough Inspection Report. - Form available at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Missing copy of emergency instructions or emergency procedures plan - Form available at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Missing list of designated Class A/B & C Operators - Form available at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
1, 2, 3 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.

NOV Number: E0020261328 (Pending)    Issue Date: 5/19/2026    Expiration Date: 7/18/2026    View NOV Form

Tanks Violations
2 Failed to Empty the Tank to 1" or Less
2 Submit Notification Form For Tank Status Change - Change status of tank to out of service until repairs are completed.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/1990 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 12/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/21/2025 7/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/21/2025 7/21/2026
Overfill Prev Device Overfill Drop Tube Valve 7/21/2025 7/21/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/21/2025 7/21/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/21/2025
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Pass 5/4/2023



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/1990 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 12/1/1989 Red Tag Issue Date: 5/19/2026
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/21/2025 7/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/21/2025 7/21/2026
Overfill Prev Device Overfill Drop Tube Valve 7/21/2025 7/21/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/21/2025 7/21/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/21/2025
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Fail 5/18/2026



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/1990 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 12/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/21/2025 7/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/21/2025 7/21/2026
Overfill Prev Device Overfill Drop Tube Valve 7/21/2025 7/21/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 9/25/2025 9/25/2028
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/21/2025 7/21/2028
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/21/2025
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 9/25/2025
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Pass 9/29/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms