Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2031408
Status: Active
Facility Name: Sushila Properties, Inc.
Address: 28 West 125 Warrenville Road Warrenville, IL 60555
County: Du Page
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01836
Green Tag Issue Date: 7/24/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Sushila Properties, Inc.
Owner Address: 1031 Granger Road Bartlett, IL 60103
Owner Status: Current Owner
Purchase Date: 9/30/2008
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/1/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/24/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035035 Sushila Properties, Inc. Current Owner 9/30/2008
U0027493 Amoco Oil Company Former Owner 1/1/1994
U0000552 BP Products North America, Inc. Former Owner 1/1/1994

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
01-1965 Eligible 1/9/2006 2/14/2006 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/17/2004
OSFM First Notify Date: 2/15/1996 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 4/1/1994 Red Tag Issue Date:
Last Used Date: 8/13/2004 Fee Due: $0.00
Product Date: 4/1/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/17/2004
OSFM First Notify Date: 2/15/1996 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 4/1/1994 Red Tag Issue Date:
Last Used Date: 8/13/2004 Fee Due: $0.00
Product Date: 4/1/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/17/2004
OSFM First Notify Date: 2/15/1996 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 4/1/1994 Red Tag Issue Date:
Last Used Date: 8/13/2004 Fee Due: $0.00
Product Date: 4/1/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 15000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/18/2004 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 8/27/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/1/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/7/2024 10/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 10/7/2024 10/7/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 10/7/2024 10/7/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 4/24/2023 4/24/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/24/2023 4/24/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025
Spill Contain Device Single Wall Spill Bucket 4/24/2023 4/24/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/7/2024



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/18/2004 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 8/27/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/1/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/7/2024 10/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 10/7/2024 10/7/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 10/7/2024 10/7/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 4/24/2023 4/24/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/24/2023 4/24/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025
Spill Contain Device Single Wall Spill Bucket 4/24/2023 4/24/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/7/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/24/2023 4/24/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/24/2023 4/24/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/24/2023 4/24/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/24/2023 4/24/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/24/2023 4/24/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/24/2023 4/24/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/24/2023 4/24/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/24/2023 4/24/2026
Leak Detect - Piping Sump Sensor 10/7/2024 10/7/2025

MFD Motorfuel Dispensing Forms

No Forms Found