Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2030101
Status: Inactive
Facility Name: Sheraton Suites
Address: 121 Northwest Point Boulevard Elk Grove Village, IL 60007
County: Cook
Property Parcel: 08-21-202-072-0000
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: BB003607
Green Tag Issue Date: 2/3/2026
Green Tag Expire Date: 12/31/2028
MFD Type: N/A

Owner Details

Owner Name: Chicago UMA, LLC
Owner Address: 5801 Southfield Expressway Detroit, MI 48228
Owner Status: Current Owner
Purchase Date: 7/15/2015
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/22/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040633 Chicago UMA, LLC Current Owner 7/15/2015
U0009734 Sheraton Suites Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261653 (Referred to Legal)    Issue Date: 6/26/2026    Expiration Date: 8/25/2026    View NOV Form

Tanks Violations
Facility Financial responsibility must be reported yearly - The form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility

NOV Number: E0020262245 (Pending)    Issue Date: 9/18/2026    Expiration Date: 11/17/2026    View NOV Form

Tanks Violations
1 Submit Notification Form For Tank Status Change - The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm Place tank out of service

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 2500 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/19/1992 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 8/1/1990 Red Tag Issue Date:
Last Used Date: 9/17/2026 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 6/11/2025 6/11/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 6/11/2025 6/11/2026
Overfill Prev Device Overfill Drop Tube Valve 6/11/2025 6/11/2028
Piping Fiberglass Chase Not applicable Not applicable
Piping Copper Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 6/11/2025 6/11/2028
Tank Fiberglass Double Wall Owens Corning Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall Precision Test (Tank) Pass 8/5/2022

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found