Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2029491
Status:
Closed
Facility Name:
Bruce Nagel
Address:
1043 Paramount Pkwy Batavia, IL 60510
County:
Kane
Property Parcel:
Facility Type:
Commercial / Retail
Owner Type:
Private
Green Tag Decal:
N001555
Green Tag Issue Date:
2/23/2012
Green Tag Expire Date:
12/31/2014
MFD Type:
N/A
Owner Details
Owner Name:
Bruce Nagel
Owner Address:
1043 Paramount Pkwy Batavia, IL 60510
Owner Status:
Current Owner
Purchase Date:
6/1/1989
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
12/28/2012
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0018845
Nagel , Bruce
Current Owner
6/1/1989
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
13-1204
11/6/2013
Removal Log
01086-2013REM
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/6/2013
OSFM
First Notify Date:
2/27/1992
Abandoned Material:
Current Age:
24
Abandoned Date:
Install Date:
6/1/1989
Red Tag Issue Date:
Last Used Date:
12/1/2011
Fee Due:
$0.00
Product Date:
6/1/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
2/13/2012
2/13/2015
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik Jr.
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Flexible Double Wall Total Containment Enviroflex non-corrosive
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
1000
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/6/2013
OSFM
First Notify Date:
2/27/1992
Abandoned Material:
Current Age:
24
Abandoned Date:
Install Date:
6/1/1989
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
6/1/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
2/13/2012
2/13/2015
Leak Detect - Piping
Gravity Feed
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging EBW Auto-Stik Jr.
Overfill Prev Device
Less than 25 gallon fills
N/A
N/A
Piping
Flexible Double Wall Total Containment Enviroflex non-corrosive
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms