Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2029288
Status: Active
Facility Name: Pal Mart, Inc.
Address: 415 New Avenue Romeoville, IL 60441
County: Will
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002900
Green Tag Issue Date: 6/15/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Ahmad Zahdan
Owner Address: 12345 S. Keeler Ave. Alsip, IL 60803
Owner Status: Current Owner
Purchase Date: 1/1/2013
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/15/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/15/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0032207 Zahdan, Ahmad Current Owner 1/1/2013
U0031124 Saraf, Inc. Former Owner 10/25/2004
U0014941 Texor Petroleum Company, Inc. Former Owner 5/24/2002
U0025946 P.D.V. Midwest Refining L.L.C. Former Owner 5/1/1997
U0015441 The Uno Ven Company Former Owner 12/31/1967
U0007703 Sweeney Oil Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
01060-2025CAT Cathodic Protection Approved / Issued 8/13/2025 8/14/2025 2/17/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020251917 (Pending)    Issue Date: 7/30/2025    Expiration Date: 9/28/2025    View NOV Form

Tanks Violations
1, 2, 3 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Unable to open STP for all tanks due to them being rusted on, and not having a handle for lifting.
Facility Control station not equipped with an emergency shutoff switch
Facility Facility Operation and Maintenance Plan not completed or available.
Facility Financial responsibility must be reported yearly
1, 2, 3 Install corrosion protection under dispensers to protect exposed flex connectors and other metal portions of product piping. - Dispenser 7/8 has no corrosion protection for flex connector.
Facility Missing copies of 30 day Walkthrough Inspection Report.
Facility Missing copy of emergency instructions or emergency procedures plan
Facility Missing list of designated Class A/B & C Operators
1, 2, 3 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.

NOV Number: E0020251918 (Pending)    Issue Date: 7/30/2025    Expiration Date: 9/28/2025    View NOV Form

Tanks Violations
Facility Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - Attendant can not see all dispensers due to signage covering all of the windows, and there is no camera system.
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - No communication system.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 4/13/2010 Abandonment Log 00304-2010ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
10-0176 Eligible 5/11/2010 7/1/2010 $10,000
10-0176 Eligible 10/6/2014 12/4/2014 $10,000
15-1148 Eligible 1/8/2016 1/26/2016 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 9/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/2/2023 6/2/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/2/2023 6/2/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/2/2023 6/2/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/15/2025 8/15/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/16/2025 6/16/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 6/16/2025 6/16/2026
Overfill Prev Device Ball Float Vent Valve 6/2/2023 6/2/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/2/2023 6/2/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 6/16/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 6/2/2023



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 9/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/2/2023 6/2/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/2/2023 6/2/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/2/2023 6/2/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/15/2025 8/15/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/16/2025 6/16/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 6/16/2025 6/16/2026
Overfill Prev Device Ball Float Vent Valve 6/2/2023 6/2/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/2/2023 6/2/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 6/16/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 6/2/2023



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 9/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/2/2023 6/2/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/15/2025 8/15/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/2/2023 6/2/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/2/2023 6/2/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/16/2025 6/16/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 6/16/2025 6/16/2026
Overfill Prev Device Ball Float Vent Valve 6/2/2023 6/2/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/2/2023 6/2/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 6/16/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 6/2/2023



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/1991 Abandoned Material: Inert material mixed with portland cement
Current Age: 33 Abandoned Date: 4/13/2010
Install Date: 9/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/16/2007 11/16/2010
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/4/2009 2/4/2010
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 250
Overfill Prev Device Ball Float Vent Valve
Piping Flex Connector Steel N/A N/A
Piping Flexible Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found