Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2029003
Status: Active
Facility Name: Circle K #6716
Address: 2001 S. Bridge Street Yorkville, IL 60560
County: Kendall
Property Parcel: 05-05-400-020
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA03948
Green Tag Issue Date: 1/12/2026
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: RDK Ventures LLC
Owner Address: 1120 W. Warner Rd. Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 1/7/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/27/2027

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/12/2026 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures LLC Current Owner 1/7/2010
U0013849 Shell Oil Products Former Owner 4/14/1997
U0027449 Equilon Enterprises, LLC Former Owner 8/8/1994
U0018472 Pride Petro Co Inc Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00072-2026UPG Upgrade Approved / Issued 1/20/2026 1/20/2026 7/21/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020253248 (Pending)    Issue Date: 12/12/2025    Expiration Date: 2/10/2026    View NOV Form

Tanks Violations
Facility Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - 175.210 g) All dispensing units shall be readily visible from the control station without assistive devices. However, as an alternative, in the event that the attendant's view of a dispenser is permanently obstructed, or if a dispenser is located so that activity at the dispenser is not readily visible, closed-circuit cameras that provide a view of each side of the dispensing unit and project an image on a screen at least 6 inches in diagonal located at the control station may be used. The cameras shall be allowed to sweep to provide a view of multiple dispensing locations, but must provide a view on the screen of each dispensing unit at least every 30 seconds. In lieu of the closed-circuit camera, the facility may elect to have an emergency stop that shall be located at least 20 and not more than 50 feet from the dispenser that has a permanently obstructed view. Using an emergency stop in lieu of the closed circuit camera pursuant to this subsection (g) must be approved in advance by OSFM. If a closed-circuit camera or viewing screen is inoperable and cannot provide surveillance of dispensing units to the attendant at the control station, and an emergency stop has not been approved by OSFM and provided in lieu of the camera as provided in this subsection (g), self-service dispensing of fuel at these dispensers is prohibited.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-1143 Eligible 10/1/2008 11/24/2008 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/12/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 11/30/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/30/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/18/2025 6/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/18/2025 6/18/2026
Overfill Prev Device Overfill Drop Tube Valve 6/27/2024 6/27/2027
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026
Spill Contain Device Single Wall Spill Bucket 6/27/2024 6/27/2027
Tank Jacketed Steel Single Wall Total Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Western Co-Flex Precision Test (Piping) Pass 6/18/2025



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/12/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/30/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/18/2025 6/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/18/2025 6/18/2026
Overfill Prev Device Overfill Drop Tube Valve 1/21/2026 1/21/2029
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026
Spill Contain Device Double Wall Spill Bucket 1/21/2026 1/21/2029
Tank Jacketed Steel Single Wall Total Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Western Co-Flex Precision Test (Piping) Pass 6/18/2025
Tank Jacketed Steel Single Wall Total Containment Precision Test (Tank) Pass 5/30/2019



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/12/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/30/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/18/2025 6/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/18/2025 6/18/2026
Overfill Prev Device Overfill Drop Tube Valve 10/1/2024 10/1/2027
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026
Spill Contain Device Single Wall Spill Bucket 6/27/2024 6/27/2027
Tank Jacketed Steel Single Wall Total Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Western Co-Flex Precision Test (Piping) Pass 6/18/2025



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Ultra Low Sulfur Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/12/1990 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/30/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/18/2025 6/18/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/18/2025 6/18/2026
Overfill Prev Device Overfill Drop Tube Valve 6/27/2024 6/27/2027
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 8/15/2024 8/15/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 10/7/2020 10/7/2021
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2025 6/18/2026
Spill Contain Device Double Wall Spill Bucket 6/27/2024 6/27/2027
Tank Jacketed Steel Single Wall Total Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 7/13/2023
Piping Flexible Double Wall Western Co-Flex Precision Test (Piping) Pass 6/18/2025



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Ultra Low Sulfur Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/12/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/30/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/18/2025 6/18/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/18/2025 6/18/2026
Overfill Prev Device Overfill Drop Tube Valve 6/27/2024 6/27/2027
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 8/15/2024 8/15/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 10/7/2020 10/7/2021
Leak Detect - Piping Discriminating Sump Sensor with positive shutdown 8/24/2021 8/24/2022
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2025 6/18/2026
Spill Contain Device Double Wall Spill Bucket 6/27/2024 6/27/2027
Tank Jacketed Steel Single Wall Total Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 7/13/2023
Piping Flexible Double Wall Western Co-Flex Precision Test (Piping) Pass 6/18/2025
Tank Jacketed Steel Single Wall Total Containment Precision Test (Tank) Pass 7/1/2021



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Ultra Low Sulfur Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/12/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 11/30/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/30/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/21/2025 7/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/18/2025 6/18/2026
Overfill Prev Device Overfill Drop Tube Valve 6/27/2024 6/27/2027
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026
Spill Contain Device Single Wall Spill Bucket 6/27/2024 6/27/2027
Tank Jacketed Steel Single Wall Total Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Western Co-Flex Precision Test (Piping) Pass 6/18/2025



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/12/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/30/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/18/2025 6/18/2026
Overfill Prev Device Overfill Drop Tube Valve 6/27/2024 6/27/2027
Piping Flexible Double Wall Western Co-Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026
Spill Contain Device Double Wall Spill Bucket 6/27/2024 6/27/2027
Tank Jacketed Steel Single Wall Total Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Western Co-Flex Precision Test (Piping) Pass 6/18/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026



Name\ID 17/17-S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor with positive shutdown 12/11/2025 12/11/2026



Name\ID 17M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026



Name\ID 18/18-S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026



Name\ID 19/19-S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026



Name\ID 20/20-S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2025 6/18/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/15/2024 8/15/2027
Leak Detect - Piping Sump Sensor 6/18/2025 6/18/2026

MFD Motorfuel Dispensing Forms

No Forms Found