Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0041404 |
SGGF Ventures, LLC |
Current Owner |
12/24/2024 |
| U0040783 |
9754 Irving Park Real Estate, LlC |
Former Owner |
10/28/2021 |
| U0018178 |
Marathon Car Care Inc |
Former Owner |
8/19/1996 |
| U0025038 |
Schiller Park Marathon Inc |
Former Owner |
4/24/1996 |
| U0018178 |
Marathon Car Care Inc |
Former Owner |
4/7/1992 |
| U0009663 |
Marathon Oil Company |
Former Owner |
12/31/1967 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 96-2173 |
4/7/1998 |
Removal Log |
|
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
B-11 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/22/1991 |
|
Abandoned Material: |
|
| Current Age: |
39 |
|
Abandoned Date: |
|
| Install Date: |
12/26/1986 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Sacrificial Anode Cathodic Protection |
2/20/2024 |
2/20/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
2/18/2026 |
2/18/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
2/18/2026 |
2/18/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/21/2024 |
10/21/2027 |
|
Piping
|
Fiberglass Double Wall |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/21/2024 |
10/21/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall
|
Precision Test (Piping)
|
Pass
|
2/18/2026
|
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
2/18/2026
|
Tank Number 2
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/22/1991 |
|
Abandoned Material: |
|
| Current Age: |
39 |
|
Abandoned Date: |
|
| Install Date: |
12/26/1986 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Sacrificial Anode Cathodic Protection |
2/20/2024 |
2/20/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
2/18/2026 |
2/18/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
2/18/2026 |
2/18/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/21/2024 |
10/21/2027 |
|
Piping
|
Fiberglass Double Wall |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Single Wall Transition Sump |
No passing test found |
No passing test found |
|
Spill Contain Device
|
Double Wall Spill Bucket |
12/20/2024 |
12/20/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall
|
Precision Test (Piping)
|
Pass
|
2/18/2026
|
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
2/18/2026
|
Tank Number 3
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/22/1991 |
|
Abandoned Material: |
|
| Current Age: |
39 |
|
Abandoned Date: |
|
| Install Date: |
12/26/1986 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Sacrificial Anode Cathodic Protection |
2/20/2024 |
2/20/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
2/18/2026 |
2/18/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
2/18/2026 |
2/18/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/21/2024 |
10/21/2027 |
|
Piping
|
Fiberglass Double Wall |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Single Wall Transition Sump |
No passing test found |
No passing test found |
|
Spill Contain Device
|
Single Wall Spill Bucket Insert |
10/21/2024 |
10/21/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall
|
Precision Test (Piping)
|
Pass
|
2/18/2026
|
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
2/18/2026
|
Tank Number 4
| Capacity: |
550 |
|
Petroleum Use: |
Consumptive Use on Premises for Heating |
| Product: |
Heating Oil |
|
CERCLA Substance: |
|
| Status: |
Abandoned in place |
|
CAS Code: |
|
| Regulated Status: |
State |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/22/1991 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
39 |
|
Abandoned Date: |
4/7/1998 |
| Install Date: |
12/26/1986 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 5
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Exempt |
|
Removed Date: |
11/23/1986 |
|
OSFM
First Notify Date: |
4/30/1986 |
|
Abandoned Material: |
|
| Current Age: |
37 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 6
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Exempt |
|
Removed Date: |
11/23/1986 |
|
OSFM
First Notify Date: |
4/30/1986 |
|
Abandoned Material: |
|
| Current Age: |
37 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 7
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Exempt |
|
Removed Date: |
11/23/1986 |
|
OSFM
First Notify Date: |
4/30/1986 |
|
Abandoned Material: |
|
| Current Age: |
37 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 8
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Exempt |
|
Removed Date: |
11/23/1986 |
|
OSFM
First Notify Date: |
4/30/1986 |
|
Abandoned Material: |
|
| Current Age: |
37 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 9
| Capacity: |
550 |
|
Petroleum Use: |
|
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Exempt |
|
Removed Date: |
11/23/1986 |
|
OSFM
First Notify Date: |
4/30/1986 |
|
Abandoned Material: |
|
| Current Age: |
37 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 10
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
6/30/1997 |
|
Abandoned Material: |
|
| Current Age: |
29 |
|
Abandoned Date: |
|
| Install Date: |
11/20/1996 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/20/1996 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
2/18/2026 |
2/18/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
2/18/2026 |
2/18/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/21/2024 |
10/21/2027 |
|
Piping
|
Fiberglass Double Wall |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Single Wall Transition Sump |
No passing test found |
No passing test found |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/21/2024 |
10/21/2027 |
|
Tank
|
Fiberglass Single Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall
|
Precision Test (Piping)
|
Pass
|
2/18/2026
|
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
2/18/2026
|
Tank Number 11
| Capacity: |
300 |
|
Petroleum Use: |
Consumptive Use on Premises for Heating |
| Product: |
Heating Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Exempt |
|
Removed Date: |
4/7/1998 |
|
OSFM
First Notify Date: |
1/1/1902 |
|
Abandoned Material: |
|
| Current Age: |
|
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
12/1/1973 |
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found